Description
Narrow Band FM Multi-channel UHF Transceiver
Manufacturer
ETC2 [List of Unclassifed Manufacturers]
Datasheet
The 'modem' mentioned is a 1200 baud RS232 semi-intelligent unit (Transmit keyed when valid serial data is
present, so no separate TX control needed. Coding in the datastream also permits the receiver to ignore noise
and only output valid serial data). This is a half duplex unit, so collisions between transmitted and received
packets must be dealt with by the user.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
TR2Ms on both ends should be configured to required operating frequency using GOCHAN
command before starting to use the internal 1200 baud modem, because the P1-P3 pins will be used
as Modem Data pins and the modem will operate on the last serially selected channel after
SETMOD command is used to enable the Modem.
Note:
Baud rate used for Modem is half that of used for serial configuration. Attached RS232 devices
should be set with the following:
TXD (Pin 3) of a Serial Port can be switched from PGM (Pin C10) to MOD TXD (Pin C11) with no
RS232 driver in between. However, MOD RXD (Pin C12) requires an RS232 line driver before it
can be connected to RXD (pin 2) of a serial port. Some of the RS232 line drivers can be powered
from the regulated +4.4V out (Pin C8).
Radiometrix Ltd
Name
MOD TX_ON
MOD NC
MOD NC
RSSI
MOD NC
AF out
NC
+4.4V out
0V
PGM
MOD TXD
MOD RXD
MOD NC
1200bps, 8 Data bits, No Parity, 1/2 stop bits, no flow control
Pin description of TR2M with Modem mode selected
Figure 7: TR2M interfaced to PC serial port in modem mode
TXE (MOD TX_ON) (C1)
Function
Leave open
Leave open
DC level between 0.5V and 2.5V. 60dB dynamic range
Leave open
Modem tones or noise present
Leave open
Regulated DC supply. 75mA max. drain. Present if unit is powered
Ground
Serial programming/configuration input at RS232 level
RS232 data input (true). 10k pullup to 4V
Leave open
Open = normal modem operation. Low = constant TX (for test). 10k pullup to 4V
Inverted RS232 data out (to inverting buffer like MAX232)
AF in (MOD NC) (C3)
P2 (MOD RXD) (C12)
RXD (MOD NC) (C7)
P1 (MOD TXD) (C11)
SQF (MOD NC) (C5)
TXD (MOD NC) (C2)
P3 (MOD NC) (13)
+4.4V out (C8)
AF out (C6)
PGM (C10)
GND (C9)
RSSI (C4)
TR2M Data Sheet
SW1
RS232 driver
VDD
Serial COM Port
6
7
8
9
4
5
1
2
3
RXD
TXD
SGD
page 8