g4a-1a-pe Omron Corporation, g4a-1a-pe Datasheet - Page 2

no-image

g4a-1a-pe

Manufacturer Part Number
g4a-1a-pe
Description
Pcb Power Relay ? G4a
Manufacturer
Omron Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
g4a-1a-pe 12VDC
Manufacturer:
TOREX
Quantity:
54 156
Part Number:
g4a-1a-pe DC24V
Manufacturer:
OMRON
Quantity:
500
Part Number:
g4a-1a-pe-1
Manufacturer:
Harting
Quantity:
30 000
Part Number:
g4a-1a-pe-12V
Manufacturer:
OMRON
Quantity:
30 000
Part Number:
g4a-1a-pe-12VDC
Manufacturer:
OMRON
Quantity:
20 000
Company:
Part Number:
g4a-1a-pe-12VDC
Quantity:
3 655
Company:
Part Number:
g4a-1a-pe-24VDC
Quantity:
3 655
Company:
Part Number:
g4a-1a-pe-5VDC
Quantity:
3 655
Company:
Part Number:
g4a-1a-pe-DC12V
Quantity:
3 655
Company:
Part Number:
g4a-1a-pe-DC24V
Quantity:
3 655
Note: P level: λ 60 = 0.1 x 10
with Motor Load
With Overload
With Inverter Load
Note: The data shown above are initial values.
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (ref. value)
250 VAC:
Inrush current: 80 A, 0.3 s (cosø= 0.7)
Break current: 20 A (cosø = 0.9)
250 VAC:
Inrush current: 80 A (cosø= 0.7)
Break current: 80 A (cosfø= 0.7)
100 VAC:
Inrush current: 200 A (0-P)
Break current: 20 A
Contact resistance
Operate time
Release time
Max. Operating Frequency
Insulation resistance
Insulation resistance
Dielectric strength
Shock resistance
Vibration resistance
Endurance
Ambient temperature
Ambient humidity
Weight
PCB Power Relay – G4A
Contact Ratings
Endurance
Characteristics
Load conditions
Load conditions
Load conditions
-6
/operation (with an operating frequency of 120 operations/min).
20 A at 250 VAC
20 A
250 VAC
20 A
5,000 VA
100 mA at 5 VDC
100 mΩ max.
20 ms max.
10 ms max.
Mechanical: 18,000 operations/hr
1000 MΩ max. (at 500 VDC)
100 MΩ max. (at 500 VDC)
4,500 VAC 50/60 Hz for 1 min between coil and contacts
1,000 VAC 50/60 Hz for 1 min between contacts of same polarity
Destruction: 1,000 m/s
Malfunction: 200 m/s
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Mechanical: 2,000,000 operations min. (at 18,000 operations/hr)
Motor load: 100,000 operations min. (ON/OFF: 1.5 s)
Inverter load: 30,000 operations min. (ON: 3 s, OFF: 5 s)
Operating: -20°C to 60°C (with no icing)
Operating: 5% to 85%
Approx. 25 g
ON: 1.5 s
OFF: 1.5 s
ON: 1.5 s
OFF: 99 s
ON: 3 s
OFF: 5 s
2
2
Switching frequency
Switching frequency
Switching frequency
200,000 operations
1,500 operations
30,000 operations
Electrical endurance
Electrical endurance
Electrical endurance
151