hx50-p ETC-unknow, hx50-p Datasheet

no-image

hx50-p

Manufacturer Part Number
hx50-p
Description
Current Transducer
Manufacturer
ETC-unknow
Datasheet
Current Transducer HX 03..50-P
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Notes :
080124/13
V
R
R
V
I
V
V
V
X
V
V
TCV
TCV
t
BW
T
T
m
dCp
Primary nominal
C
r
A
S
OUT
C
d
e
W
OE
OH
OUT
current rms
L
L
Electrical data
Accuracy-Dynamic performance data
General data
I
OE
OUT
PN
10
15
20
25
50
3
5
(A)
1)
2)
Also operate at ±12V power supplies, measuring range reduced to ±2.5x I
Small signal only to avoid excessive heating of the magnetic cores
Output voltage (Analog) @ ± I
Output internal resistance
Load resistance
Supply voltage (± 5 %)
Current consumption
Rms voltage for AC isolation test, 50Hz, 1 min
Partial discharge extinction voltage rms @ 10 pC
Impulse withstand voltage, 1.2/50 µs
Accuracy @ I
Linearity error (0 .. ± I
Electrical offset voltage @ T
Hysteresis offset voltage @ I
after an excursion of 1 x I
Temperature coefficient of V
Temperature coefficient of V
Response time to 90% of I
Frequency bandwidth (- 3 dB)
Ambient operating temperature
Ambient storage temperature
Mass
Creepage distance
Isolation material group
Standards
measuring range
Primary current
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
I
± 9
± 15
± 30
± 45
± 60
± 75
± 150
PM
(A)
PN
, T
A
= 25°C (excluding offset)
PN
Primary conductor
diameter x turns
1)
)
0.6d x 20T
0.8d x 12T
1.1d x 6T
1.4d x 4T
1.6d x 3T
1.6d x 2T
1.2 x 6.3 x 1T
PN
PN
(mm)
A
PN
OE
OUT
P
= 25°C
step
= 0,
, R
2)
(% of reading)
L
= 10 k , T
A
= 25°C
HX 03-P
HX 05-P
HX 10-P
HX 15-P
HX 20-P
HX 25-P
HX 50-P
Type
± 4
< 50
± 15
< ± 15
> 3
< ± 1
< ± 1
< ± 40
< ± 15
< ± 1.5
± 0.1
50
- 25 .. + 85 °C
- 25 .. + 85 °C
8
I
EN50178: 1997
10
1
6
3
5.5
RoHS since
date code
48011
45341
45340
45352
45319
45351
45288
% of I
% of I
mV/K
%/K
m m
kHz
mA
mV
mV
k
µs
kV
kV
kV
PN
PN
V
V
g
PN
Features
Advantages
Applications
Application domain
I
PN
Galvanic isolation between primary
and secondary circuit
Hall effect measuring principle
Isolation voltage 3000V
Low power consumption
Extended measuring range (3 x I
Power supply from ±12V to ±15V
Isolated plastic case recognized
according to UL94-V0.
Low insertion losses
Easy to mount with automatic
handling system
Small size and space saving
Only one design for wide current
ratings range
High immunity to external
interference.
AC variable speed drives
DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Electrical appliances
Industrial
= 3 .. 50 A
www.lem.com
Page 1/2
PN
)

Related parts for hx50-p

hx50-p Summary of contents

Page 1

Current Transducer HX 03..50-P For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data Primary nominal Primary current Primary conductor current rms ...

Page 2

Dimensions HX 03..50-P (in mm 0.0394 inch) HX 03...25-P HX 03..25-P 19 Max. 3 10. OUT 10.85 Mechanical characteristics General tolerance LEM reserves the ...

Related keywords