DS1922E-F5 MAXIM [Maxim Integrated Products], DS1922E-F5 Datasheet - Page 15

no-image

DS1922E-F5

Manufacturer Part Number
DS1922E-F5
Description
High-Temperature Logger iButton with 8KB Data-Log Memory
Manufacturer
MAXIM [Maxim Integrated Products]
Datasheet
The DS1922E is set up for its operation by writing
appropriate data to its special function registers, which
are located in the two register pages. The settings in
the Mission Control register determine which format (8
or 16 bits) applies and whether old data can be over-
written by new data once the data-log memory is full.
An additional control bit can be set to tell the DS1922E
to wait with logging data until a temperature alarm is
encountered.
Bit 5: Start Mission Upon Temperature Alarm
(SUTA). This bit specifies whether a mission begins
immediately (includes delayed start) or if a temperature
alarm is required to start the mission. If this bit is 1, the
device performs an 8-bit temperature conversion at the
selected sample rate and begins with data logging only
if an alarming temperature (high alarm or low alarm)
was found. The first logged temperature is when the
alarm occurred. However, the mission sample counter
does not increment. This functionality is guaranteed by
design and not production tested.
Note: During a mission, there is only read access to this register. Bits 6 and 7 have no function. They always read 1 and cannot be
written to 0. Bits 1 and 3 control functions that are not available with the DS1922E. Bit 1 must be set to 0. Under this condition the
setting of bit 3 becomes a “don’t care.”
ADDRESS
0213h
High-Temperature Logger iButton with 8KB
BIT 7
______________________________________________________________________________________
1
BIT 6
1
Mission Control
SUTA
BIT 5
BIT 4
RO
Bit 4: Rollover Control (RO). This bit controls whether,
during a mission, the data-log memory is overwritten
with new data or whether data logging is stopped once
the data-log memory is full. Setting this bit to 1 enables
the rollover and data logging continues at the begin-
ning, overwriting previously collected data. If this bit is
0, the logging and conversions stop once the data-log
memory is full. However, the RTC continues to run and
the MIP bit remains set until the Stop Mission command
is performed.
Bit 2: Temperature Logging Format Selection
(TLFS). This bit specifies the format used to store tem-
perature readings in the data-log memory. If this bit is
0, the data is stored in 8-bit format. If this bit is 1, the
16-bit format is used (higher resolution). With 16-bit for-
mat, the most significant byte is stored at the lower
address.
Bit 0: Enable Temperature Logging (ETL). To set up
the device for a temperature-logging mission, this bit
must be set to logic 1. The recorded temperature val-
ues start at address 1000h.
BIT 3
(X)
Data-Log Memory
TLFS
BIT 2
Mission Control Register
BIT 1
0
BIT 0
ETL