DS2756E+TR MAXIM [Maxim Integrated Products], DS2756E+TR Datasheet - Page 17

no-image

DS2756E+TR

Manufacturer Part Number
DS2756E+TR
Description
High-Accuracy Battery Fuel Gauge with Programmable Suspend Mode
Manufacturer
MAXIM [Maxim Integrated Products]
Datasheet
STATUS REGISTER
The default values for the Status Register bits are stored in lockable EEPROM in the corresponding bits of address
31h. A Recall Data command for EEPROM block 1 recalls the default values into the Status Register bits. The
format of the Status Register is shown in Figure 15. The function of each bit is described in detail in the following
paragraphs. Note that all bits are Read Only.
Figure 15. STATUS REGISTER FORMAT
PIE1, PIE0—Programmable Suspend Interrupt Enable. A non zero value in these bits enables the DS2756 to enter
Suspend mode, and sets the Suspend Period (t
DS2756 from entering Suspend mode and allows the DS2756 to enter Sleep mode.
*Each EEPROM block is read/write until locked by the LOCK command, after which it is read-only.
Table 2. Memory Map
ADDRESS (HEX)
1C to 1F
09 to 0B
90 to FF
02 to 06
12 to 17
20 to 3F
40 to 5F
60 to 7F
80 to 8F
0C
0D
0E
1A
1B
00
01
07
08
0F
10
11
18
19
PIE1
bit 7
Reserved
Status Register
Reserved
EEPROM Register
Special Feature Register
Reserved
Voltage Register MSB
Voltage Register LSB
Current Register MSB
Current Register LSB
Accumulated Current Register MSB
Accumulated Current Register LSB
Reserved
Temperature Register MSB
Temperature Register LSB
Average Current Register MSB
Average Current Register LSB
Reserved
EEPROM, block 0
EEPROM, block 1
EEPROM, block 2
SRAM
Reserved
PIE0
bit 6
PMOD
bit 5
SUS
RNAOP
bit 4
) for the low power oscillator timeout. A value of 00b disables the
DESCRIPTION
Address 01h
17 of 26
UVEN
bit 3
bit 2
IOS
OBEN
bit 1
OVD
bit 0
READ/WRITE
R/W*
R/W*
R/W*
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R
R
R
R
R

Related parts for DS2756E+TR