Feature Integration Technology Inc.
Datasheet
7-4
3-0
7-4
3-0
Bit
Bit
Bit
7.82
7.83
7.84
0
T3_JUMP_LOW_EN
FAN T3 Control Register 2 – Index D7h
FAN T3 Control Register 3 – Index D8h
FAN T3 Control Register 4 – Index D9h
FAN2_WEIGHT
FAN1_WEIGHT
FAN3_WEIGHT
Name
Name
Name
-
R/W
R/W Default
R/W
R/W
R/W Default
R/W
R/W Default
R
0
0
0
0
0
Set 1 that FAN speed will jump to SEC2SPEED when temperature under
BOUND1TEMP Hystersis.
Set 0 that FAN speed will decrease to SEC2SPEED by slop value (CR9B)
when temperature under FAN1 Boundary Hystersis.
Temperature 3 to FAN2 weight setting register:
0: T3 independent with FAN2.
1: Proportion of T3 to FAN2 is 1/15
2: Proportion of T3 to FAN2 is 2/15.
…..
F: Proportion of T3 to FAN2 is 15/15
Temperature 3 to FAN1 weight setting register:
0: T3 independent with FAN1.
1: Proportion of T3 to FAN1 is 1/15
2: Proportion of T3 to FAN1 is 2/15.
…..
F: Proportion of T3 to FAN1 is 15/15
Reserved
Temperature 3 to FAN3 weight setting register:
0: T3 independent with FAN3.
1: Proportion of T3 to FAN3 is 1/15
2: Proportion of T3 to FAN3 is 2/15.
…..
F: Proportion of T3 to FAN3 is 15/15