4.3.6 Transmit Status Register (TSR) Offset 04H (Read)
4.3.7 Receive Configuration (RCR) Offset 0CH (Write)
4.3.8 Receive Status Register (RSR) Offset 0CH (Read)
FIELD
FIELD
FIELD
FIELD
4.3.9 Inter-frame gap (IFG) Offset 16H (Read/Write)
6:4
6:0
7
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
AX88190A
INT_RG Interrupt Regeneration
NAME
NAME
NAME
NAME
OWC
MON
MPA
ABT
COL
PRO
PHY
PRX
PTX
FAE
SEP
AM
DIS
IFG
AB
AR
CR
FO
-
-
-
-
-
Out of window collision
Reserved
Transmit Aborted
Transmit Collided
Reserved
Packet Transmitted
Reserved
Monitor Mode
buffered into memory.
PRO : Promiscuous Mode
Enable the receiver to accept all packets with a physical address.
AM : Accept Multicast
Enable the receiver to accept packets with a multicast address. That multicast address must
pass the hashing array.
AB : Accept Broadcast
Enable the receiver to accept broadcast packet.
AR : Accept Runt
Enable the receiver to accept runt packet.
SEP : Save Error Packet
Enable the receiver to accept and save packets with error.
Reserved
Receiver Disabled
Multicast Address Received.
Missed Packet
FIFO Overrun
Frame alignment error.
CRC error.
Packet Received Intact
Reserved
Inter-frame Gap. Default value 15H.
0 : Enable interrupt regeneration function in multifunction application. (default) But must
1 : Monitor Mode, the input packet will be checked on NODE ADDRESS and CRC but not
1: Disable
0 : Normal Operation
Indicates that the transmission collided at least once with another station on the network.
Indicates the AX88190A aborted transmission because of excessive collision.
Indicates transmission without error.
set CIS relative Enable function first, than the function will be open.