G5SB-14DC12 OMRON [Omron Electronics LLC], G5SB-14DC12 Datasheet - Page 2

no-image

G5SB-14DC12

Manufacturer Part Number
G5SB-14DC12
Description
PCB Relay
Manufacturer
OMRON [Omron Electronics LLC]
Datasheet
■ Contact Ratings
Note: P level: λ
■ Characteristics
Note: 1. The data shown above are initial values.
■ Approved Standards
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp = 40°C
Note: Electrical durability tests are performed at 70°C.
124
Load
Rated load
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
Min. permissible load
Contact resistance (See note 2.)
Operate time (See note 3.)
Release time (See note 3.)
Insulation resistance (See note 4.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Life expectancy (See note 5.)
Ambient temperature
Ambient humidity
Weight
G5SB
2. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
3. The operating time is possible with the operating voltage imposed with no contact bounce at an ambient temperature of 23°C.
4. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
5. The electrical life data items shown are possible at 23°C.
Model
PCB Relay
60
=0.1 x 10
–6
operation (with an operating frequency of 120 operations/min.)
G5SB
5 to 24 VDC
Coil ratings
Resistive load
3 A (NO)/3 A (NC) at 125 VAC
5 A (NO)/3 A (NC) at 125 VAC
5 A (NO) at 250 VAC
3 A (NC) at 250 VAC
5 A (NO)/3 A (NC) at 30 VDC
Ag alloy
5 A (NO)/3 A (NC)
250 VAC, 30 VDC
5 A (NO)/3 A (NC)
1,250 VA, 150 W (NO)
750 VA, 30 W (NC)
10 mA at 5 VDC
100 mΩ max. initial
10 ms max.
5 ms max.
1,000 MΩ min.
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
8 kV (1.2 x 50 μs)
Destruction:10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction:10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction:1,000 m/s
Malfunction:Energized: 100 m/s
Non-energized: 100 m/s
Mechanical:
Electrical:
Switching frequency: 1,800 operations per hour
Operating: –40°C to 70°C with no icing or condensation
Operating: 5% to 85%
Approx. 6.5 g
5,000,000 operations (18,000 operations per hour)
200,000 operations: 3 A (NO)/3 A (NC) at 125 VAC resistive load
50,000 operations: 5 A (NO)/3 A (NC) at 125 VAC resistive load
50,000 operations: 5 A (NO) at 250 VAC resistive load
10,000 operations: 3 A (NC) at 250 VAC resistive load
10,000 operations: 5 A (NO)/3 A (NC) at 30 VDC resistive load
2
3 A, 125 VAC (resistive) NC only
2 A, 125 VAC (resistive) NC only
5 A, 250 VAC (resistive) NO only
3 A, 250 VAC (resistive) NO only
5 A, 30 VDC (resistive) NO only
(approx. 100G)
2
(approximately 10G)
2
(approximately 10G)
Contact ratings
6,000
Number of test operations

Related parts for G5SB-14DC12