SVC101D-07A

Manufacturer Part Number
SVC101D-07A
Description
SVC Varistors Type
Manufacturer
SAMWHA [SAMWHA ELECTRIC]
Datasheet
Applications
Power Supply Circuit Protection
Line circuit
Varistor voltage selection table (Z
Notes :
① The power supply voltage must not exceed the maximum
② Since independent wiring loads and capacitive loads cause
③ The bold faced portions of the type letters vary.
AC/DC
single-phase circuit
128
The Protection of semiconducting elements such as
diodes, thyristors, transistors, IC and relays against
transient Voltages.
Similar protection of many types of measuring
instruments, control machinery and communication
equipment and broadcasting equipment against
inductive lightning and switching surges.
Protection of general purpose electrical equipment,
domestic mechinery and appliances. TV and radios
and similar consumer products against lightning and
switching surges.
allowable circuit voltage.
the voltage build-up at the time of opening or closing the
load, use SVC having a varistor voltage as high as
possible.(*mark)
Power Supply Voltage
SAMWHA CAPACITOR Co., Ltd.
100V AC
200V AC
12V DC
24V DC
AC
three-phase circuit
L
)
SVC271D -□□A*
SVC471D -□□A*
SVC201D -□□A
SVC221D -□□A
SVC241D -□□A
SVC391D -□□A
SVC431D -□□A
SVC220D -□□B
SVC390D -□□B
Type
Line and groud circuit
Varistor voltage selection table(Z
AC/DC
single-phase circuit
Telecommunication Circuit Protection
Varistor voltage selection guied
Notes :
① When subjected to megger testing(500V DC), the insulation
② When subjected to dielectric strength test(1000V AC).
Notes :
The varistor SVC has a capacitance value. Take not of this when
applying them to high-frequency signal circuits.
Power Supply Voltage
Power Supply Voltage
Select varistors taking a note of operating conditions
peculiar to the equipment.
resistance value can decrease due to the leakage current of
the SVC, To avoid this remove the varistor or use* marked
SVC.
remove the SVC or use** marked SVC.
200V AC
100V AC
24V AC
12V DC
SVC751D -□□A to SVC112D -□□A*
AC
three-phase circuit
E
SVC182D -□□A**
)
SVC220D -□□B
SVC820D -□□A
SVC820D -□□A
SVC431D -□□A
SVC471D -□□A
SVC180D -□□B
SVC390D -□□B
Type
Type
Switching Circuit Protection
Protection of relay
(Contact coil)
Varistor voltage selection guide
Notes :
① The power supply voltage must not exceed the maximum
② Pay due attention to the surge energy generated by the
③ Select SVC referring to the pulse lifetime rating.
④ To further reduce the tendency of sparking across the
Application Notes
Overcurrent protection
When surges exceed the rating for the SVC, short-circuits or
damages can be expected. Take following precautions.
allowable circuit voltage of the SVC
load.
contacts connect a capacitors parallel with the SVC. This will
also protect the equipment from electromagnetic wave
jamming.
Power Supply Voltage
100V DC
100V AC
12V DC
24V DC
SVC220D -□□B
SVC390D -□□B
SVC201D -□□A
SVC221D -□□A
SVC241D -□□A
SVC271D -□□A
SVC151D -□□A
Protection of
semiconductors
Type
① Connect the SVC at a position nearer to the equipment than
② If the overcurrent protection device “Ⅰ” can not be installed
③ When “Z
Installation
① When operated at location near heating element or
② When operated in dusty or dirty locations, or exposed to
Molding
When shielding the SVC in a resin molding, take a note of the
materials used and temperature, since they influence the
reliability. For further information please contact SAMWHA
Current, power and energy rating vs, temperature
Electrical Characteristics
Applicable fuse
rated current(A)
“Ⅰ” operates (trips or blow off the fuse).
Operating ambient temperature
Storage temperature
Voltage temperatur coefficient
Insulation resistance(at500V)
the overcurrent protection device “Ⅰ” (fuse, MCCB) as is
shown in the diagram.
When the SVC is shorted, the overcurrent protection device
in “ Ⅰ” position, connect a fuse at “Ⅱ” position. Select fuse
rated current for the SVC referring to the following table.
ground install an ELCB (Earth Leakage Circuit Breaker). If not
possible, connect a fuse or thermal fuse at “Ⅲ”position.
exposed to direct sun light, confirm that the ambient
temparature range.
corrosive atomospheres, or where metallic powders or salt
can be expected, be sure to mount within a protective
enclosure.
SVC
2
”SVC is connected between the equipment and
1 to 2
05A
05B
SVC Varistors Type
DISC Ceramic Capacitors
2 to 3
07A
07B
3 to 5
10A
10B
-40℃ to +125℃
-40℃ to +85℃
Over 1000MΩ
-0.05% ℃
3 to 10
14A
14B
5 to 15
20A
20B
129