SI3230 SILABS [Silicon Laboratories], SI3230 Datasheet - Page 91

no-image

SI3230

Manufacturer Part Number
SI3230
Description
Manufacturer
SILABS [Silicon Laboratories]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3230-E-FM
Manufacturer:
SILICONLX
Quantity:
20 000
Part Number:
SI3230-E-FMR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
SI3230-E-FTR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Part Number:
SI3230-EFTR
Manufacturer:
SILICON
Quantity:
21 495
Part Number:
SI3230-EFTR
Manufacturer:
SILABS
Quantity:
20 000
Part Number:
SI3230-FM
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
SI3230-FM
Quantity:
360
Part Number:
SI3230-M-E-FMR
Manufacturer:
ST
0
Company:
Part Number:
SI3230M-E-FM
Quantity:
300
Part Number:
SI3230M-E-FMR
Manufacturer:
INTEL
Quantity:
171
Part Number:
SI3230M-FM
Manufacturer:
ROHM
Quantity:
8 600
Bit
4
3
2
1
0
HYSTEN
ZSEXT
SWDB
DCFIL
Name
LCVE
Impedance Internal Reference Resistor Disable.
When enabled, this bit removes the internal reference resistor used to synthesize ac
impedances for 600 + 2.1 µF and 900 + 2.16 µF so that an external resistor reference
may be used.
0 = Internal resistor used to generate 600 + 2.1 µF and 900 + 2.16 µF impedances.
1 = Internal resistor removed from circuit.
Battery Switch Debounce.
When enabled, this bit allows debouncing of the battery switching circuit only when tran-
sitioning from V
0 = No debounce used.
1 = 60 ms debounce period used.
Voltage-Based Loop Closure.
Enables loop closure to be determined by the TIP-to-RING voltage rather than loop cur-
rent.
0 = Loop closure determined by loop current.
1 = Loop closure determined by TIP-to-RING voltage.
DC-DC Converter Squelch.
When enabled, this bit squelches noise in the audio band from the dc-dc converter con-
trol loop.
0 = Voice band squelch disabled.
1 = Voice band squelch enabled.
Loop Closure Hysteresis Enable.
When enabled, this bit allows hysteresis to the loop closure calculation. The upper and
lower hysteresis thresholds are defined by indirect registers 28 and 43, respectively.
0 = Loop closure hysteresis disabled.
1 = Loop closure hysteresis enabled.
BATH
to V
Preliminary Rev. 0.96
BATL
external battery supplies (EXTBAT = 1).
Function
Si3230
91