V300A12E24B1 VICOR [Vicor Corporation], V300A12E24B1 Datasheet - Page 2

no-image

V300A12E24B1

Manufacturer Part Number
V300A12E24B1
Description
FasTrak Micro E-Grade Family DC-DC Converter Module
Manufacturer
VICOR [Vicor Corporation]
Datasheet
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
ELECTRICAL CHARACTERISTICS
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
Note: 300 Vin models do not have overvoltage turn-off.
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,
Parameter
Input voltage
Output voltage setpoint
Parameter
Efficiency (typ.)
Ripple and noise, p-p (typ.)
Output OVP setpoint (nom.)
Dissipation, standby (typ.)
Load regulation (max.)
Current limit (typ.)
Short circuit current (typ.)
Parameter
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Parameter
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
MODULE OUTPUT VOLTAGE RELATED SPECIFICATIONS
MODULE INPUT SPECIFICATIONS
MODULE OUTPUT SPECIFICATIONS
MODULE OPERATING SPECIFICATIONS
24 Vin
48 Vin
300 Vin
375 Vin
contact Vicor applications engineering at 800-927-9474.
24 Vin
17.5
15.3
37.8
Min
180
250
Min
18
36
10
Set your site on VICOR at www.vicorpower.com
3.3V
76.5
120
115
115
4.3
3.4
0.4
±0.005
48 Vin
±0.5
34.9
30.5
78.8
Typ
300
375
Typ
80.0
± 5
24
48
105
115
115
6.3
4.4
0.4
5V
84.0
14.3
12V
170
115
115
5.0
0.2
300 Vin
Max
Max
375
425
175
153
N/A
110
36
75
±1
85.5
17.8
15V
150
115
115
7.0
0.2
86.0
28.1
24V
150
115
115
Surge Withstand
4.9
0.2
FasTrak Mini E-Grade Family
375 Vin
100
400
500
243
212
446
32.7
50
86.5
28V
180
115
115
4.6
0.3
88.0
55.7
48V
115
115
4.0
0.2
55
% / °C
Units
Unit
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
±% Vout
%
% Iout.
%
%
%
% Iout
Watts
Volts
Unit
mV
%
Notes
<100 ms surge withstand
Nominal input; full load; 25°C
Notes
Nominal input; 80% load; 25°C
Nominal input; full load;
25°C; 20MHz BW
25°C; recycle input voltage to
restart ( 1 minute off )
No load; nominal input
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
Notes
Typical value
Typical value
Typical value
Notes
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below
90% of nominal, a minimum load of 10% of
maximum rated power may be required.
Rev. 1.0
Page 2 of 8

Related parts for V300A12E24B1