uwr-1.2-6000-d12a C&D Technologies., uwr-1.2-6000-d12a Datasheet
![no-image](/images/no-image-200.jpg)
uwr-1.2-6000-d12a
Related parts for uwr-1.2-6000-d12a
uwr-1.2-6000-d12a Summary of contents
Page 1
... SMT-on-pcb construction, these UWR Models are able to bring you 7-15W (@ up to 6A) in the standard 1" x 2" package from which most competitors can only get 5-10W (@ 3-4A). All UWR’s deliver their full output power over ambient temperature ranges from – ...
Page 2
... BOTTOM VIEW 0.200 (5.08) DIMENSION ARE IN INCHES (MM) Technical enquiries email: sales@murata-ps.com, tel: MDC_UWR Models.F01 Page Package (Case, Pinout) C14, P22 C14, P22 C14, P22 C14, P22 C14, P22 C14, P22 C14, P22 C14, P22 C14, P22 ...
Page 3
... Volts, unlimited duration TBD/3.4/4.4 Volts, unlimited duration 7.1/16/18 Volts, unlimited duration Current limited. Devices can withstand sus- tained output short circuits without damage. +100°C –40 to +105°C Technical enquiries email: sales@murata-ps.com, tel: MDC_UWR Models.F01 Page 508 339 3000 ...
Page 4
... Operation under no-load conditions will not damage 12/15V converters. However they may not meet all listed specifications. Filtering and Noise Reduction All A-Series UWR DC/DC Converters achieve their rated ripple and noise specifications using the external input and output capacitors specified in the Performance/Functional Specifications table. In critical applications, input/output noise may be further reduced by installing additional external I/O caps ...
Page 5
... O Start-Up Time is the interval between the time at which a ramp- OUT Start-Up Time assumes the converter is turned off via the OUT = desired output voltage. O Technical enquiries email: sales@murata-ps.com, tel: MDC_UWR Models.F01 Page –8.25 O – 2.527) O –15 O –15 – 1.24) O – ...
Page 6
... Temperature Derating Curves for UWR 7-15W A-Series The thermal performance of A-Series UWR 7-15 Watt DC/DC Converters is depicted in the derating curves shown below. All devices, when operated at full load, in still ambient air, over their full specified input voltage range, can safely operate to T maximum. All models, other than the D12A models (10-18 Volt ...
Page 7
... Typical Performance Curves for UWR 7-15W A-Series UWR-1.5/6000-D12A Efficiency vs. Line and Load 10V 12V 18V 0.6 1.2 1.8 2.4 3 3.6 Load Current (Amps) UWR-1.5/6000-D24A Efficiency vs. Line and Load ...
Page 8
... Typical Performance Curves for UWR 7-15W A-Series UWR-2.5/6000-D12A Efficiency vs. Line and Load 10V 12V 18V 0.6 1.2 1.8 2.4 3 3.6 4.2 Load Current (Amps) UWR-2.5/6000-D24A Efficiency vs. Line and Load 18V 24V 36V ...
Page 9
... Typical Performance Curves for UWR 7-15W A-Series UWR-12/1250-D12A Efficiency vs. Line and Load 10V 12V 18V 0.1 0.2 0.4 0.5 0.7 0.8 Load Current (Amps) UWR-12/1250-D24A Efficiency vs. Line and Load 18V 24V 36V 0.1 0.2 0.4 0.5 0.7 0.8 Load Current (Amps) www ...
Page 10
... Typical Performance Curves for UWR 7-15W A-Series UWR-12/1250-D48A Efficiency vs. Line and Load 36V 48V 75V 0.1 0.2 0.4 0.5 0.7 0.8 Load Current (Amps) UWR-15/1000-D12A Efficiency vs. Line and Load 10V 12V 18V 0.1 0.2 0.3 0.4 0.6 0.7 Load Current (Amps) UWR-15/1000-D24A Efficiency vs ...
Page 11
... Typical Performance Curves for UWR 7-15W A-Series Output Ripple and Noise (PARD nominal 2.5V @ 6A, two external 0.47µF output capacitors.) IN OUT 20mV, 1µsec/div, 20MHz BW Output Ripple and Noise (PARD nominal 3.3V @ 4.25A, two ext. 0.47µF output capacitors.) IN OUT 20mV, 1µsec/div, 20MHz BW Output Ripple and Noise (PARD) ...
Page 12
... Standard UWR-3.3/4250-D48A, 48V current (4.5A), negative on/off polarity control and a special competitive- compatible trim. UWR-3.3/4500-D48ANT accepts trim adjustments to ±10% of nominal V not to exceed 15W of maximum output power. Users should carefully consider the amount of trim added since excessive positive trim may exceed the overvoltage protection ...