TS18 SUNTAN [Suntan Capacitors], TS18 Datasheet - Page 6

no-image

TS18

Manufacturer Part Number
TS18
Description
MULTILAYER CERAMIC CHIP CAPACITOR - SMD
Manufacturer
SUNTAN [Suntan Capacitors]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TS180
Manufacturer:
ST
0
Part Number:
TS180 TSI180
Manufacturer:
ST
0
Part Number:
TS180M
Manufacturer:
ST
0
Part Number:
TS180M
Manufacturer:
ST
Quantity:
20 000
Part Number:
TS1815ILT
Manufacturer:
ST
0
Part Number:
TS1851
Manufacturer:
ST
0
Part Number:
TS1851AILT
Manufacturer:
ST
Quantity:
20 000
Part Number:
TS1851I
Manufacturer:
PERICOM
Quantity:
4 490
Part Number:
TS1851ID
Manufacturer:
ST
Quantity:
20 000
Part Number:
TS1851IDT
Manufacturer:
ST
Quantity:
20 000
Part Number:
TS1851ILT
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
TS1851ILT
Quantity:
2 840
MULTILAYER CERAMIC CHIP CAPACITOR - SMD
TS18
13. Temperature Cycle
14. Moisture Resistance ,steady state
Dielectrics
NPO
X7R/X5R
Dielectrics
NPO
X7R/X5R
Y5V
Suntan
®
Technology Company Limited
Specification
No remarkable visual damage
Cp change within ±2.5% or ±0.25pF,
whichever is larger.
No remarkable visual damage
Cp change within ±7.5%
Specification
No remarkable visual damage
Cp change within ±5% or ±0.5pF,
whichever is larger.
Cp<10pF, Q≥200+10Cp;
10≤Cp<30pF, Q≥275+2.5Cp
Cp≥30pF, Q≥350
R*C≥1000MΩ or 50Ω·F, whichever
is smaller
Cp change within ±12.5%
DF:Not more than 2 times of
initial value
R*C≥1000MΩ or 50Ω·F, whichever
is smaller
No remarkable visual damage
Cp change within ±30%
DF:Not more than 1.5 times of
initial value
R*C≥1000MΩ or 50Ω·F, whichever
is smaller
Website: www.suntan.com.hk
Email: info@suntan.com.hk
Testing Condition
To perform 5 cycles of the stated
environment:
Step
Measurement to be made after being kept at
room temperature for 24±2hrs (C0G) or
48±4hrs (X7R, X5R, Y5V) at room
temperature, then measure.
*Initial measurement for high dielectric
constant type
Perform a heat treatment at 140~150℃ for
1hr and let sit for 48±4hrs at room
temperature.
Perform the initial measurement.
Testing Condition
Test temperature: 40±2℃
Humidity: 90~95% RH
Testing time: 500 ±12hrs
Measurement to be made after being kept at
room temperature for 24±2hrs (C0G) or
48±4hrs (X7R, X5R, Y5V)
*Initial measurement for high dielectric
constant type
Perform a heat treatment at 140~150℃ for
1hr and let sit for 48±4hrs at room
temperature.
Perform the initial measurement.
1
2
3
4
Temperature
Min. operating
Temp.+0/-3℃
25℃
Max. operating
Temp.+0/-3℃
25℃
Tel: (852) 8202 8782
Time
30min
2~3 min
30 min
2~3 min
Fax: (852) 8208 6246
Suntan
®

Related parts for TS18