pd600-230-48 TDK Corp., pd600-230-48 Datasheet - Page 2

no-image

pd600-230-48

Manufacturer Part Number
pd600-230-48
Description
Ac/dc Front End Power Module
Manufacturer
TDK Corp.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PD600-230-48
Quantity:
60
Part Number:
pd600-230-48/PO1
Manufacturer:
IR
Quantity:
1 000
Part Number:
pd600-230-48/PO1
Quantity:
60
O U T L I N E S P E C I F I C A T I O N ( c o n t i n u e d )
MONITORING AND ALARM
Remote sensing (+S/-S):
Output voltage (TRM):
Parallel operation (PC):
Remote on/off (CNT):
Auxiliary supply (AUX):
Inverter operation:
Signal (IOG):
Over current protection
adjustment (IMAX):
Please refer to Instruction Manual for further details.
ENVIRONMENTAL
Operating temperature:
Ambient temperature:
Storage temperature:
E L E C T R I C A L S P E C I F I C A T I O N
Model No.
PD600-230-48
PD600-230-48/P01
PD800A-230-48/C01
PS800A-230-48/SC01 88-265VAC
PD800A-230-48
PD800A-230-48/P01
(*1) Output power will vary depending upon input voltage, 404/505W at input voltage 88/100-225VAC.
(*2) Minimum required airflow 1.5m/s for operation of PD800A module. For details of thermal design, refer to instruction manual.
DESCRIPTION OF COVER TYPE
PD600-230-48/PO1 - PD800A-230-48/PO1
PD600 - PD800A-230-48/C01
PD600 - PD800A-230-48/SC01 - PD600 - PD800A-230-48
AVAILABLE OPTIONS
Option
P01
S
T
Explanation
Version with input pins for soldering on PCB
Version without the mainswitch
Version with mounting studs without threads
Input
(*1)
88-265VAC
88-265VAC
88-265VAC
88-265VAC
88-265VAC
Compensation of voltage drop due
to wire resistance
Through external voltage source or
adding external resistor
Output current can be equally shared up to
5 units of the same model
Output of PSU can be turned on and off
without disconnecting the input
11 to 13VDC, 30mA max.
Power supply for external signals
Good operation condition of power module
Can be monitored (open collector)
102% - 120%
The setting can be changed through
external voltage source or resistor
-20 to +85°C baseplate temperature
PD600: -20 to +45°C
(convection cooling with heatsink
PD800A: -20 to +50°C
(forced air cooling, 1.5m/s air flow)
-40°C to +85°C
50.5VDC A
50.5VDC A
50.5VDC A
50.5VDC A
50.5VDC A
50.5VDC A
187-265VAC (*1)
Max. Output power
Single-sided aluminium-plate (external protection against contact is necessary).
5-sided aluminium cover.
606W
606W
808W
808W
808W
808W
12.0
12.0
16.0
16.0
16.0
16.0
Amps
Inlet
Yes
No
Yes
Yes
Yes
No
AC
ENVIRONMENTAL (continued)
Vibration:
Shock:
Weight:
SAFETY APPROVALS*
EN60950, UL1950, UL1459, CSA22.2 No.950-95, CSA22.2 No.225
telecommunication equipment.
*Contact Technical Sales for current status of approvals.
EMC
Conducted emission:
Conducted and radiated
emission
Susceptibility:
Power factor correction:
Protection against high
energy impulses from
the mains-side:
WARRANTY
Warranty:
All specifications guaranteed worst case unless otherwise noted.
Model No.
Suffix/P
Suffix/S
Suffix/T
Switch
Yes
No
Yes
No
Yes
No
AC
Note
Optional model
Input
pins
No
Yes
No
No
No
Yes
amplitude 0.825mm, constant (maximum
5G) X,Y,Z 1 hour each (non-operating)
>20G (in package)
750g typ.
EN55022 B (SCO1)
EN55022 A, EN55022 B (SC01 suffix)
EN61000-4-2 & 3, 4, 5, 6 (Level 3)
GSM 11.22
EN61000-3-2
VDE 0160 (W2)
year including parts and labour.
cover
No
No
Yes
Yes
No
No
Full
plate Cooling
Yes
Yes
No
No
Yes
Yes
Top
Convection cooling
Convection cooling
Forced air cooling (*1)
Forced air cooling (*1)
Forced air cooling (*1)
Forced air cooling (*2)
Series PD

Related parts for pd600-230-48