S15-48-3.3 BTCPOWER [Broadband TelCom Power, Inc.], S15-48-3.3 Datasheet
S15-48-3.3
Related parts for S15-48-3.3
S15-48-3.3 Summary of contents
Page 1
... EMI/RFI • UL 60950 recognized, TUV EN60950 and CSA C22.2 No. 60950-00 Certified • Meets conducted limits of FCC Class B and CEI IEC61204-3 Class B with external filter • MTBF of 850,000 hours @ 50°C (MIL-HDBK-217F) 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. Inc S15-48-3.3 Rev4 1-30-05 ...
Page 2
... Output Current at 60°C (Amps) 300 LFM Free Air 200 LFM 4.5 4.5 4.5 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower . Output Voltage Current (Volts) (Amps) 3.3 4.5 Output Current at 80°C (Amps) 300 LFM Free Air 200 LFM 4.5 1.8 2.9 PS S15-48-3.3 Rev4 1-30- Efficiency 75% Load (%) 88 300 LFM 4 ...
Page 3
... N/A N/A 0.04 0 100,000 50 100 800 2 87 1500 1000 1000 10 1000 225 250 275 1 -10 +10 1,100,000 20.7(0. S15-48-3.3 Rev4 1-30- UNIT mV(pk-pk %Vo % VDC VDC VDC M pF KHz ...
Page 4
... There are two ON/OFF control options: positive logic (S15-48-3.3) and negative logic (S15-48-3.3N). Both are referenced to Vin-. Pin 1 is the "Enable" pin, connecting a TTL compatible pin. A TTL control signal to this pin, according to the specification, turns the unit on or off ...
Page 5
... An external capacitor will improve the stability of the unit. Also in many applications, the user has to use decoupling capacitors at the output load, to ensure the hold up time for the load. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower S15-48-3.3 Rev4 1-30-05 ...
Page 6
... C0 = 1.0 uF 250Vdc film capacitor C1 = 1.0 uF 100Vdc ceramic capacitor L1 = 2.2 mH Common mode choke meets the Input Transient Withstand (ITW) The unit can withstand input transient voltage with 100V/100ms pulse and never be damaged. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower S15-48-3.3 Rev4 1-30-05 ...
Page 7
... C with the airflow of 0, 100 and 200LFM (0, and 1 F 0.5m/s and 1m/s). Others Other curve and waveforms presented include output voltage vs. current curve (Fig 16) and input current ripple waveform at full load condition (Fig 17) 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower S15-48-3.3 Rev4 1-30-05 ...
Page 8
... For this example, the unit total start up time (t3- t1) is typically 300us. Broadband TelCom Power, Inc. – Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com 48Vin 3.3Vout 4.5A Fig 7. Start up waveform Fig 8. Start up using On/Off pin 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower S15-48-3.3 Rev4 1-30-05 ...
Page 9
... Fig 12. Efficiency at nominal input (48V) vs. load at different ambient temperatures without air flow, the input voltage is 48V. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower T M 36V 48V 75V 1.8 2.7 3.6 4.5 Output current (A) 25°C 40°C 55°C 1.8 2.7 3.6 4.5 Output current ( S15-48-3.3 Rev4 1-30-05 ...
Page 10
... Over Current Protection Curve Fig 16. Output voltage vs current showing current limit point and converter shut down point 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower 0LFM 100FM(0.5m/s) 200LFM(1m/ Ambient Temperature(°C) P10 S15-48-3.3 Rev4 1-30- ...
Page 11
... Fig 17. Input current ripple with full output load at 48V input (10mA/div), time scale: 1 s/div Broadband TelCom Power, Inc. – Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com 48Vin 3.3Vout 4.5A 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. BTCPower BTCPower T M P11 S15-48-3.3 Rev4 1-30-05 ...