ACS108-6SN STMICROELECTRONICS [STMicroelectronics], ACS108-6SN Datasheet - Page 6

no-image

ACS108-6SN

Manufacturer Part Number
ACS108-6SN
Description
AC switch family Transient voltage protected AC Switch (ACS)
Manufacturer
STMICROELECTRONICS [STMicroelectronics]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACS108-6SN
Manufacturer:
ST
0
Part Number:
ACS108-6SN
Quantity:
4 370
Part Number:
ACS108-6SN-TR
Manufacturer:
STMicroelectronics
Quantity:
59 014
Part Number:
ACS108-6SN-TR
Manufacturer:
STM
Quantity:
7 500
Part Number:
ACS108-6SN-TR
Manufacturer:
ST
0
Part Number:
ACS108-6SN-TR
Manufacturer:
ST
Quantity:
20 000
Company:
Part Number:
ACS108-6SN-TR
Quantity:
4 000
Part Number:
ACS108-6SN-TR/EB
Manufacturer:
ST
0
AC line switch - basic application
2
2.1
2.1.1
6/11
AC line switch - basic application
The ACS108-6S switch is triggered by a negative gate current flowing from the gate pin G.
The switch can be driven directly by the digital controller through a resistor as shown in
Figure 13.
Thanks to its overvoltage protection and turn-off commutation performance, the ACS108-6S
switch can drive a small power high inductive load with neither varistor nor additional turn-off
snubber.
Figure 13. Typical application program
Protection against overvoltage: the best choice is ACS
In comparison with standard triacs, which are not robust against surge voltage, the ACS108-
6S is over-voltage self-protected, specified by the new parameter V
in two operating conditions: in case of turn-off of very inductive load, and in case of surge
voltage that can occur on the electrical network.
High inductive load switch-off: turn-off overvoltage clamping
With high inductive and low RMS current loads the rate of decrease of the current is very
low. An overvoltage can occur when the gate current is removed and the OUT current is
lower than I
As shown in
current decreases (1). The load current reaches the holding current level I
ACS turns off (3). The water valve, as an inductive load (up to 15 H), reacts as a current
generator and an overvoltage is created, which is clamped by the ACS (4). The current flows
through the ACS avalanche and decreases linearly to zero. During this time, the voltage
across the switch is limited to the clamping voltage V
of the load is dissipated in the clamping section that is designed for this purpose. When the
energy has been dissipated, the ACS voltage falls back to the mains voltage value (5).
H
Power supply
Figure 14
.
and
Figure
MCU
V
V
15, at the end of the last conduction half-cycle, the load
dd
ss
Rg
CL
. The energy stored in the inductance
Valve
ACS108-6S
CL
. This feature is useful
AC Mains
H