SR3 STEALTH_MICROWAVE [Stealth Microwave, Inc.], SR3 Datasheet - Page 6

no-image

SR3

Manufacturer Part Number
SR3
Description
Manufacturer
STEALTH_MICROWAVE [Stealth Microwave, Inc.]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SR3.3-LF-T7
Manufacturer:
PROTEK
Quantity:
20 000
Part Number:
SR3.3.TC
Manufacturer:
SAMSUNG
Quantity:
39
Part Number:
SR3.3.TC
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
Part Number:
SR3.3.TCT
Manufacturer:
Semtech
Quantity:
3 000
Part Number:
SR3.3.TCT
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
Company:
Part Number:
SR3.3.TCT
Quantity:
1 320
Part Number:
SR30-10PE-6P(74)
Manufacturer:
Schneider
Quantity:
1
Part Number:
SR3010-TP
Manufacturer:
MCCSEMI
Quantity:
20 000
Part Number:
SR30100PT
Manufacturer:
PHOTRON
Quantity:
20 000
Company:
Part Number:
SR3010MTR-G
Quantity:
1 456
Part Number:
SR3015-100MLA
Manufacturer:
ABC
Quantity:
30 000
Part Number:
SR3015-100MLB
Manufacturer:
ABC
Quantity:
30 000
Status Byte
OVRT
REV
STATUS
SUMERR
SYSRESET
TEMP
THRML
VER
VSWR
bit 7
Fan
Email: sales@stealthmicrowave.com ♦ Web site: www.stealthmicrowave.com
VSWR
bit 6
---
---
---
---
---
---
---
---
---
Current
Alarm
bit 5
1007 Whitehead Road Ext., Trenton, NJ 08638
Tel: (609) 538-8586 ♦ Fax: (609) 538-8587
Returns status of over temperature alarm bit.
Mode0: “ON” – Amp’s temperature over 60° C, “OFF” – normal
condition
Mode1: 1 byte, 1 – Amp’s temperature over 60° C, 0 – normal
condition
Returns reverse power (Not available in all amplifiers).
Mode0: “0” – “1023” relative to the reverse power
Mode1: 2 bytes LSB first, 0 - 1023
Returns amplifier alarm status byte.
Mode0: Hexadecimal “00” – “FF”
Mode1: 1 byte, 0-255
See below for status byte description.
Returns status of summary error alarm bit.
Mode0: “ON” – Alarm condition exists, “OFF” – normal condition
Mode1: 1 byte, 1 – Alarm condition exists, 0 – normal condition
Resets the controller.
Returns amplifier base plate temperature in degrees Celsius.
Mode0: “xx C”
Mode1: 2 bytes, LSB first
Returns status of thermal alarm bit. Occurs when amplifier exceeds
75° C
Mode0: “ON” – Amp in thermal shutdown, “OFF” – normal condition
Mode1: 1 byte, 1 – Amp in thermal shutdown, 0 – normal condition
Displays the controller software version.
Returns status of VSWR alarm bit (Not available in all amplifiers)
Mode0: “ON” – High VSWR condition exists, “OFF” – normal
condition
Mode1: 1 byte, 1 – High VSWR condition exists, 0 – normal
Shutdown
Thermal
bit 4
Temperature
bit 3
High
Power
bit 2
Over
SR3 Series
Amplifier
On/Off
bit 1
Summary
bit 0
Error

Related parts for SR3