Configurable Signal Conditioning Enclosure
Interface Panelettes
National Instruments also offers interface panelettes, which expand
the functionality of the CA-1000. Interface panelettes include
traditional interface controls and displays, such as rocker switches,
toggle switches, momentary switches, potentiometers, and LEDs.
Using interface panelettes, which are mounted alongside I/O
panelettes, you can change hardware inputs, trigger events, or verify
operational status. Each interface panelette includes lead wires for
connection to the screw terminals of the accessory mounted inside
the CA-1000.
Figure 1. CA-100 Panelettes Options
Table 1. CA-1000 Cabling
National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com
1
cabling to a CB-68T and CA-1000.
Device
68-pin E Series DAQ Devices (except DAQCards)
100-pin E Series DAQ Devices
Latching E Series DAQCards
DAQCard-6062E, DAQCard-6024E
Nonlatching E Series DAQCards:
DAQCard-AI-16E-4, DAQCard-AI-16XE-50
68-pin digital I/O and counter/timer devices (except DAQCards)
PCI-DIO-32HS, PXI-6533, AT-DIO-32HS,
NI 6534, NI 660x
Nonlatching 68-pin digital I/O DAQCards:
DAQCard-6533
Simultaneous sampling multifunction DAQ devices
PCI-6503
PC-DIO-24
DAQCard-DIO-24
NI 65273, PCI-DIO-963, PXI-65083, DAQPad-65083
PC-DIO-963
You can also use the SH68-68R1-EP or R6868.
Minithermocouple
Toggle Switch
4
Splits into two 50-pin connectors. See page 368 for information on using the CA-1000 with analog output products.
3
Rocker Switch
2
You can also use the PR68-68F.
BNC
3
You can use two CA-1000 enclosures with one of these devices. Please note: If you are using a NI 435x series data logger, please see Table 2 on page 358 for information on
SMB
LED
R68M-50F and PSHR68-68 shielded cable kit
R68M-50F and SHC68-68-EP
R68M-50F and SH68-68-EP
Applicable for one leg
SC-204x Series
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Strain Relief
9-Pin D-Sub
Cabling
The cabling needed to connect the CA-1000 to the measurement
device depends on the accessories installed in the CA-1000 and the
measurement device used. Some accessories installed in the CA-1000
require internal cabling to connect the accessory to the CA-1000 wall.
Use Table 1 to determine which cabling components you need,
including the cable to your measurement device.
interconnection locations, giving convenient cabling for laptop
applications by aligning the I/O connector with the location of the
PCMCIA slots on laptop computers. With the five external
interconnection locations, you can also customize desktop and rack-
mount applications for added convenience.
1
The CA-1000 also provides the flexibility of five external
2
Potentiometer
Two R50M-50F and R1005050
Banana Jack
R5OM-50F and PSH27-50F-D
Two R50M-50F and NB5
R5OM-50F and SH50-50
CB-50LP
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4
Momentary Switch
1
Connector Blocks
LEMO (B-Series)
4
PSHR68-68-D1 shielded cable kit
PSHR68-68 shielded cable kit
CB-68LPR or SCB-68
SHC68-68-EP
SH68-68-EP
SH68-68-EP
SH68-68-D1
SH1006868
N/A
N/A
N/A
N/A
MIL-Spec
Blank
1
1
2