ta1318af TOSHIBA Semiconductor CORPORATION, ta1318af Datasheet - Page 15

no-image

ta1318af

Manufacturer Part Number
ta1318af
Description
Sync Processor, Frequency Counter Ic For Tv Component Signals
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TA1318AF
Manufacturer:
TOSH
Quantity:
1 000
Part Number:
TA1318AF
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
ta1318afG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
ta1318afG(DRY
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
ta1318afG��DRY,EL��
Manufacturer:
TOSHIBA
Quantity:
1 000
Read Mode
POR (Power on reset)
HD-IN (Input signal self-check result)
V FREQ DET (Vertical frequency of SYNC or VD input selected by FREQ DET SW)
H FREQ DET (Horizontal frequency of SYNC or HD input selected by FREQ DET SW)
Note: The start trigger for frequency counting is the internal reset-pulse made from ACK of 2nd byte in BUS
consideration of Note 1, Note 2 and the other factors such as signal strength, existence of ghost signal,
H-AFC stability, I
Detects HD or H-SYNC input signal selected by INPUT SW.
How to calculate vertical frequency (X):
How to calculate horizontal frequency (X):
Decision algorithm (detection range, detection times and so on) should be determined under
(0): Status read (at second data read and subsequent)
(1): Power on (at first data read)
(0): No signal input (1): Signal input
(0000000) (0001100): No-VD
(0001101) : Vicinity of 162 Hz
(1111111) : Vicinity of 17 Hz
Convert V-FREQ DET read data into decimal and define the resulting value as Y.
Where H-FREQUENCY is 15.75 kHz/31.5 kHz, Z
Where H-FREQUENCY is 33.75 kHz/45 kHz, Z
Error of Y is 1, 0. If vertical frequency is 162 Hz or more, the frequency cannot be accurately
measured. Time constant used to separate V.SYNC from integrated C.SYNC is 9 s (error:
(0000000): No signal input (1111111): 53 kHz or more
X, Y, and Z are defined same as for V FREQ.
Error of Y is 1, 0. If horizontal frequency is 53 kHz or more, the frequency cannot be accurately
measured. When V-SYNC or VD is not input, horizontal frequency cannot be measured, resulting in
data
read mode. The counting period is between the first V-sync (VD) and the second V-sync (VD) after the
trigger.
The counted data will have 1 or 0 error according to the read timing.
To assume stable data reading;
are recommended.
Read Timing
V-SYNC or VD
Vertical frequency (X)
Horizontal frequency (X)
(0000000).
1. Set BUS reading interval more than 3 V.
2. Don’t use the first data because it is unsettled.
2
C BUS data transmission and so on via prototype TV set evaluation.
Counting period 1
Start trigger 1
(to Data 1)
1
Y
More than 3 V
(Y
(5
Z) [Hz]
Z) [kHz]
15
474.1 s
476.2 s
Counting period 2
Data 1 and
Start trigger 2
(to Data 2)
Data 2 and
Start trigger 3
TA1318AF
2003-02-19
1 s).

Related parts for ta1318af