k3hb-rnb-l1at2424 Omron Corporation, k3hb-rnb-l1at2424 Datasheet

no-image

k3hb-rnb-l1at2424

Manufacturer Part Number
k3hb-rnb-l1at2424
Description
Rotary Pulse Indicator K3hb-r
Manufacturer
Omron Corporation
Datasheet
Digital Rotary Pulse Meter Capable of 50 kHz
Measurements
• Measures High-speed Pulses at 50 kHz.
Note: No-voltage contacts of up to 30 Hz are supported.
• Six Measurement Operations Including Rotation (rpm)/
Model Number Structure
■ Model Number Legend
Base Units and Optional Boards can be ordered individually or as sets.
Base Units
1. Input Sensor Code
5. Supply Voltage
Optional Boards
Sensor Power Supply/Output Boards
Relay/Transistor Output Boards
Event Input Boards
Note: 1. CPA can be combined with relay outputs only.
Accessories (Sold Separately)
K32-DICN: Special Cable (for event inputs with 8-pin connector)
K32-BCD: Special BCD Output Cable
K3HB-R @
K33-@
K34-@
K35-@
Circumferential Speed, Ratio, and Cumulative
Provides high-speed pulse measurements up to 50 kHz of rotary
encoder or ON/OFF pulse signals and can perform rotating
measurement of high-speed rotating objects.
One Rotary Pulse Meter has 6 rotary pulse measurement functions to
support a variety of pulse measurement applications. Select the best
function for your application from the following: Rotation (rpm)/
circumferential speed/instantaneous flowrate (value proportional to
frequency), absolute ratio, error ratio, error, flow rate ratio, and passing
speed (value inversely proportional to frequency).
Rotary Pulse Indicator
K3HB-R
NB: NPN input/voltage pulse input
PB: PNP input
100-240 VAC:100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC
2. Only one of the following can be used by each Digital Indicator: RS-232C/RS-485 communications, BCD communications, or DeviceNet
Refer to Safety Precautions for All Digital Panel
Meters.
2
3
4
communications.
1
5
Base Units with Optional Boards
2. Sensor Power Supply/Output Type Code
3. Relay/Transistor Output Type Code
4. Event Input Type Code
K3HB-R@-@@@
None: None
CPA:
L1A:
L2A:
A:
FLK1A: Communications (RS-232C) + Sensor power supply
FLK3A: Communications (RS-485) + Sensor power supply
None: None
C1:
C2:
T1:
T2:
BCD : BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL)
DRT: DeviceNet (See note 2.)
None: None
1:
2:
3:
4:
A Special BCD Output Cable (sold separately) is required.
Relay contact (HH/H/LL/L: SPST-NO each)
Transistor (PNP open collector: HH/H/PASS/L/LL)
Relay contact (H/L: SPDT each)
Transistor (NPN open collector: HH/H/PASS/L/LL)
5 inputs (M3 terminal blocks), NPN open collector
8 inputs (10-pin MIL connector), NPN open collector
5 inputs (M3 terminal blocks), PNP open collector
8 inputs (10-pin MIL connector), PNP open collector
Relay output (PASS: SPDT) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 1.)
Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply
(12 VDC±10%, 80 mA) (See note 2.)
Sensor power supply (12 VDC ±10%, 80 mA)
(12 VDC±10%, 80 mA) (See note 2.)
(12 VDC±10%, 80 mA) (See note 2.)
1
2 3 4
Rubber Packing
Note: Rubber packing is provided with the Controller.
K32-P1
5
Model
CSM_K3HB-R_DS_E_7_1
1

Related parts for k3hb-rnb-l1at2424

k3hb-rnb-l1at2424 Summary of contents

Page 1

... Refer to Safety Precautions for All Digital Panel Meters. Model Number Structure ■ Model Number Legend Base Units and Optional Boards can be ordered individually or as sets. Base Units K3HB Input Sensor Code NB: NPN input/voltage pulse input PB: PNP input 5. Supply Voltage ...

Page 2

... DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended. 2. PNP input types are also available. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. max, Resolution: Approx. 10,000, Output error: ±0.5% FS ...

Page 3

... OFF voltage input impedance Must have a switching capacity higher. Must be able to properly switch load currents less sweeps of 5 min each and Z directions 2 2 (100 m/s for relay outputs) 3 times each in 3 axes, 6 directions K3HB-R 3 ...

Page 4

... Measuring roller winding speed fa: Input frequency (Hz) Prescale value ( ) 1/N 1/60 N 1/60 1/60000 1000 d/60 N 100 d/60 N d/60 N d/N 0.06 d/N Measuring the speed ratio between two rollers B A K3HB-R Frequency ( Rotation speed (rpm) Operation image (application) Measuring motor speed (for product testing) OK/NG judgment HH H PASS L LL Warning 1 ...

Page 5

... Measuring the rotation (rpm)/circumferential speed error (absolute error) between two conveyors Monitoring liquid mixture flow rate ratio Displaying the passing time for a conveyor line Distance L/( d/N)       K3HB-R Communications output To computer (remote monitoring PASS L LL Warning Linear output ...

Page 6

... NO: Voltage pulse high NC: Voltage pulse low 00 No-contact or voltage pulse input 10 Contact 10 11 Note: Set to or when there is a large variation in the display. The largest measurement range is 30 Hz. K3HB-R Meaning Prescale value menu setting Minute display h.mm.ss display mm.ss.d display (d = tenths of a second ...

Page 7

... Outputs DATA POLARITY OVER DATA VALID RUN HH H PASS L LL Refer to the K3HB Communications User's Manual (Cat. No. N129) for details on serial and DeviceNet communications. K3HB-R 100 A max Item Rating Input signal No-voltage contact input Input current for no-voltage input 10 mA Signal level ON voltage 1 ...

Page 8

... DeviceNet power supply 11 to 25-VDC DeviceNet power supply 50 mA max. (24 VDC) 64 (DeviceNet Configurator is counted as one node when connected.) 63 CRC errors Supplied from DeviceNet communications connector K3HB-R Drop line length Total drop line length (max.) (max max max max. ...

Page 9

... K3HB-R 9 ...

Page 10

... PASS Safety Standards Conformance Always use a EN/IEC-compliant power supply with reinforced insulation or double insulation for the DeviceNet power supply. The product must be used indoors for the above applicable standards to apply. K3HB DeviceNet Connector (Included) <DRT> PNP 1: V (Power supply cable: Black) ...

Page 11

... E Pulse Inputs Rotary Pulse Meter: K3HB-R NPN Input: K3HB-@NB E1 Voltage Input A E2 Input A NPN E3 COM E4 Voltage Input B E5 Input B NPN E6 COM Note: E3 and E6, as well as B6, are internally connected. D Event Inputs Models with Terminal Blocks <1> <3> N/C S-TMR HOLD RESET N/C COM BCD Output Cable ...

Page 12

... Sensor power Filter supply V O Power supply circuit (isolated) Power supply Keys Indications Drive Transistor circuit output Micro- Drive X Relay output circuit Drive DeviceNet DeviceNet circuit circuit Communi- Drive cations Communications circuit driver COM V O DC-DC Converter (isolated) K3HB-R 12 ...

Page 13

... DATA VALID signal turns ON. The DATA VALID signal will turn OFF 40 ms later, and the data will turn OFF 16 ms after that. • The K3HB BCD output model has an open collector output, so wired OR connection is possible K3HB (1) ...

Page 14

... Used to change parameters displayed. parameter settings. When changing a set value, this key is used to move along the digits. K3HB-R PV display Displays PVs, maximum values, minimum values, parameter names, and error names. Position meter Displays the position of the PV with respect to a desired scale. ...

Page 15

... Insert the adapter into the grooves on the left and right sides of the rear case and push until it reaches the panel and is fixed in place. LCD Field of Vision The K3HB is designed to have the best visibility at the angles shown in the following diagram. 10° 30° ...

Page 16

... The K3HB-P has the following six functions for receiving and displaying input pulses. F1: Passing speed F2: Cycle F3: Time difference F4: Time band F5: Measuring length F6: Interval The K3HB-C has the following three functions for receiving and displaying input pulses. F1: Individual inputs F2: Phase differential inputs F3: Pulse counting input Filters avg-t, avg-n Average Processing Average processing of input signals with extreme changes or noise smooths out the display and makes control stable ...

Page 17

... Holds the maximum and minimum measurement values. bnk-c Bank Selection Switch between 8 comparative value banks using the keys on the front panel or external inputs. A set of set comparative values can be selected as a group. copy Bank Copy Any bank settings can be copied to all banks. K3HB-R 17 ...

Page 18

... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2009 All Right Reserved. 2009.11 ...

Related keywords