dpc-64-rs232 ABACOM Technologies, Inc, dpc-64-rs232 Datasheet - Page 2

no-image

dpc-64-rs232

Manufacturer Part Number
dpc-64-rs232
Description
Dpc-64-rs232 Transceiver Module
Manufacturer
ABACOM Technologies, Inc
Datasheet
A four wire interface is used by implementing TxD, RxD, GND and CTS. The CTS flow control
line is available for users who wish to transmit more than 64 bytes. Under this condition, when the
DPC has received 64 bytes, the DPC will signal the host to pause sending data allowing it to
transmit the 64 bytes of data to the receiving DPC. Once the DPC has transmitted the data, the
CTS flow control line will toggle, allowing the DPC to receive the next 64 bytes of data from the
host.
The host terminal should be set to 9600 , 8, N, 1 and flow control should be set to ON
( substitute for other data rates)
The flow control line can be ignored if the total data to be transmitted is less than 64 bytes.
No flow control is used when uploading the received data from the DPC to the receiving host. The
relevant flow control lines have been looped back on the DPC.
Test Mode
The DPC features a test mode which is very useful to quickly test the integrity of the RF link.
When the test button is pressed, the DPC will transmit an internally generated test message to
the receiving DPC. The received test message will be displayed on the receiving host terminal
screen when running a terminal program, for example.
Note: For volume applications, the content of the preset message can be customized if required.
Specifications
Operating Temperature
Supply Voltage
Supply Current
Data Rates A version
Data Rates B version
Data Rates C version
Data Rates D version
RF Output Power
Sensitivity
RF stability
Deviation
RS-232 interface
RS-232 protocol
Max. bytes per transmission
RF i/o impedance
Antenna
Range - open field
Dimensions
32 Blair Athol Crescent Etobicoke ON M9A 1X5 Canada Tel +416-236-3858 Fax +416-236-8866
-10 to +55 C
7.5V – 15Vdc
20mA
1200bps
2400bps
4800bps
9600bps
0dBm
-107dBm
+ - 100KHz
25KHz
TxD, RxD, GND , CTS
x, 8,N,1
64
50
¼ wave wire
up to 500ft
83.5 x 53 x 15mm
ABACOM Technologies
transmit or receive
2MHz crystal
4MHz crystal
8MHz crystal
16MHz crystal
typical
typical
of centre frequency
typical
CTS only for transmit mode
flow control used
for alternative external antenna
with ¼ wave antenna
excluding DB9 connector
2