h7cx-a114-n Omron Corporation, h7cx-a114-n Datasheet - Page 31

no-image

h7cx-a114-n

Manufacturer Part Number
h7cx-a114-n
Description
Multifunction Counter/tachometer
Manufacturer
Omron Corporation
Datasheet
NPN/PNP Input Mode (imod)★
Select either NPN input (no-voltage input) or PNP input (voltage
input) as the input format.
When using a two-wire sensor, select NPN input. The same setting is
used for all external inputs.
For details on input connections, refer to Input Connections on page
page 9.
Display Color (colr)
Set the color used for the measurement value.
*1. If the tachometer output mode is set to AREA, however, the measured
*2. If the tachometer output mode is set to AREA, however, the measured
*3. If the tachometer output mode is set to AREA, however, the measured
*4. If the tachometer output mode is set to AREA, however, the measured
*5. If the tachometer output mode is set to AREA, however, the measured
*6. If the tachometer output mode is set to AREA, however, the measured
Peak/bottom Hold Enabled (dhld)
This function records the peak and bottom (i.e., minimum) after
counting starts (after turning ON the power supply or changing the
configuration selection mode or function setting). The peak value is
also held when the power supply is interrupted.
value is displayed in red when control output 1 is OFF and in green when
control output 1 is ON.
value is displayed in green when control output 1 is OFF and in red when
control output 1 is ON.
value is displayed in red when control output 1 is OFF and in orange when
control output 1 is ON.
value is displayed in orange when control output 1 is OFF and in red when
control output 1 is ON.
value is displayed in green when control output 1 is OFF and in orange
when control output 1 is ON.
value is displayed in orange when control output 1 is OFF and in green
when control output 1 is ON.
r-g
g-r
r-o
o-r
g-o
o-g
red
grn
org
*1
*2
*3
*4
*5
*6
displayed in green when
displayed in green when
displayed in red when
both control outputs 1
both control outputs 1
displayed in red when
both control outputs 1
both control outputs 1
Control output OFF
displayed in orange
displayed in orange
outputs 1 and 2 are
outputs 1 and 2 are
Measured value is
Measured value is
Measured value is
Measured value is
Measured value is
Measured value is
when both control
when both control
and 2 are OFF.
and 2 are OFF.
and 2 are OFF.
and 2 are OFF.
OFF.
OFF.
Orange (fixed)
Green (fixed)
Red (fixed)
displayed in green when
either control output 1 or
either control output 1 or
displayed in green when
control output 2 is ON.
control output 2 is ON.
displayed in red when
displayed in red when
both control outputs 1
both control outputs 1
Control output ON
displayed in orange
outputs 1 and 2 are
displayed in orange
outputs 1 and 2 are
Measured value is
Measured value is
Measured value is
Measured value is
Measured value is
Measured value is
when both control
when both control
and 2 are OFF.
and 2 are OFF.
OFF.
OFF.
Output Hysteresis (hys)
This setting can be used to prevent output chattering if the
measurement value fluctuates slightly near the set value.
The measurement value after prescaling is set.
Output OFF Delay (offd)
This function delays the timing for turning OFF comparative output by
a certain time.
The ON time can be held for the set time if the comparative result
changes in a short time.
Operation will continue and outputs will not change when holding the
value.
Set Value Upper Limit (pl-h)
Set the upper limit for the set value when it is set in run mode. The
limit can be set to between 1 and 999999.
Output Allocation (otst)
When using an H7CX-AU@-N model as 2-stage counter, each output
can be flexibly allocated to either stage 1 or 2.
The transistor output can be allocated to SV1 and the contact output
to SV2 or vice verse, as in the following tables.
H7CX-AU-N/-AUD1-N
H7CX-AUSD1-N
Key Protect Level (kypt)
Set the key protect level.
Refer to Key Protect Level on page page 36.
Pulse Cycle Measurement/Pulse Width Measurement
(calm)
Set the measurement mode to pulse cycle measurement or pulse
width measurement.
With pulse cycle measurement, the number of pulse cycles that occur
in 1 s is measured.
With pulse width measurement, the ON time for one pulse is
measured.
An input OFF period of at least 20 ms is required for pulse width
measurement.
If there is no input pulse during pulse width measurement, the
previously measured value will be held.
Display Unit (unit)
When pulse cycle measurement is used, set the display unit to Hz
(hertz) or s (seconds).
Counting Interval (intv)
If the measurement speed is 10 kHz when pulse cycle measurement
is used, set the measurement interval to 200 ms or Cont (10 ms min.).
off
on
off
on
Transistor (12-13)
Contact (3, 4, 5)
Transistor (12-13)
Transistor with diode (3, 4, 5)
Comparison value 2
Comparison value 1
Display value
Output 1
Output 1
OUTX1
OUTY2
Set the hysteresis for when
the output turns OFF.
Contact (3, 4, 5)
Transistor (12-13)
Transistor with diode (3, 4, 5)
Transistor (12-13)
Hysteresis
H7CX-A@-N
Output 2
Output 2
Tachometer
Hysteresis
31