hcts85ms Intersil Corporation, hcts85ms Datasheet
hcts85ms
Related parts for hcts85ms
hcts85ms Summary of contents
Page 1
... The HCTS85MS utilizes advanced CMOS/SOS technology to achieve high-speed operation. This device is a member of radiation hardened, high-speed, CMOS/SOS Logic Family with TTL input compatibility. The HCTS85MS is supplied lead Ceramic flatpack (K suffix SBDIP Package (D suffix). Ordering Information PART NUMBER TEMPERATURE RANGE ...
Page 2
... X A3< A3=B3 A2> A3=B3 A2< A3=B3 A2=B2 A1>B1 X A3=B3 A2=B2 A1<B1 X A3=B3 A2=B2 A1=B1 A0>B0 A3=B3 A2=B2 A1=B1 A0<B0 A3=B3 A2=B2 A1=B1 A0=B0 A3=B3 A2=B2 A1=B1 A0=B0 A3=B3 A2=B2 A1=B1 A0=B0 A3=B3 A2=B2 A1=B1 A0=B0 A3=B3 A2=B2 A1=B1 A0=B0 A3=B3 A2=B2 A1=B1 A0=B0 NOTE Logic Level Low Logic Level High Immaterial HCTS85MS TRUTH TABLE CASCADING INPUTS OUTPUTS A>B A<B A=B A> ...
Page 3
... VIL = 0.8V (Note 2) NOTES: 1. All voltages referenced to device GND. 2. For functional tests, VO ≥ 4.0V is recognized as a logic “1”, and VO ≤ 0.5V is recognized as a logic “0”. Specifications HCTS85MS Reliability Information Thermal Resistance SBDIP Package ...
Page 4
... The parameters listed in Table 3 are controlled via design or process parameters. Min and Max Limits are guaranteed but not directly tested. These parameters are characterized upon initial design release and upon design changes which affect these characteristics. Specifications HCTS85MS GROUP (NOTES 1, 2) ...
Page 5
... AC measurements assume RL = 500Ω 50pF, Input 3ns, VIL = GND, VIH = 3V. 3. For functional tests VO ≥ 4.0V is recognized as a logic “1”, and VO ≤ 0.5V is recognized as a logic “0”. TABLE 5. BURN-IN AND OPERATING LIFE TEST, DELTA PARAMETERS (+25 PARAMETER ICC IOL/IOH Specifications HCTS85MS (NOTES 1, 2) CONDITIONS TEMPERATURE GROUP B SUBGROUP ...
Page 6
... Each pin except VCC and GND will have a resistor of 1KΩ ± 5% for dynamic burn-in. OPEN NOTE: Each pin except VCC and GND will have a resistor of 47KΩ ± 5% for irradiation testing. Group E, Subgroup 2, sample size is 4 dice/wafer 0 failures. Specifications HCTS85MS TABLE 6. APPLICABLE SUBGROUPS METHOD GROUP A SUBGROUPS 100%/5004 ...
Page 7
... Variables Data (All Delta operations). Data is identified by serial number. Data header includes lot number and date of test. • The Certificate of Conformance is a part of the shipping invoice and is not part of the Data Book. The Certificate of Conformance is signed by an authorized Quality Representative. HCTS85MS 100% Interim Electrical Test 1 (T1) 100% Delta Calculation (T0-T1) 100% Static Burn-In 2, Condition hrs ...
Page 8
... AC Timing Diagrams VIH INPUT VS VIL TPLH VOH VS OUTPUT VOL TTLH VOH 80% 20% OUTPUT VOL AC VOLTAGE LEVELS PARAMETER HCTS VCC 4.50 VIH 3.00 VS 1.30 VIL 0 GND 0 HCTS85MS AC Load Circuit DUT TPHL CL = 50pF RL = 500Ω TTHL 80% 20% UNITS TEST POINT CL RL 518624 Spec Number ...
Page 9
... However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries. For information regarding Intersil Corporation and its products, see www.intersil.com HCTS85MS 5 2 A/cm HCTS85MS (A<B)IN B3 VCC (2) (1) (16) ...