hcts374ms Intersil Corporation, hcts374ms Datasheet
hcts374ms
Related parts for hcts374ms
hcts374ms Summary of contents
Page 1
... The HCTS374MS utilizes advanced CMOS/SOS technology to achieve high-speed operation. This device is a member of radiation hardened, high-speed, CMOS/SOS Logic Family. The HCTS374MS is supplied lead Ceramic flatpack (K suffi SBDIP Package (D suffix). Ordering Information PART NUMBER ...
Page 2
... =High Level (Steady State) L =Low Level (Steady State) X =Immaterial Z =High Impedance = Transition from Low to High Level Q0 =The level of Q before the indicated input conditions were established HCTS374MS TRUTH TABLE INPUTS OUTPUTS ...
Page 3
... VCC = 4.5V, VIH = 2.25V, Functional Test VIL = 0.8V (Note 2) NOTES: 1. All voltages reference to device GND. 2. For functional tests VO 4.0V is recognized as a logic “1”, and VO Specifications HCTS374MS Reliability Information Thermal Resistance SBDIP Package 10mA Ceramic Flatpack Package . . . . . . . . . . . 25mA Maximum Package Power Dissipation at +125 SBDIP Package ...
Page 4
... The parameters listed in Table 3 are controlled via design or process parameters. Min and Max Limits are guaranteed but not directly tested. These parameters are characterized upon initial design release and upon design changes which affect these characteristics. Specifications HCTS374MS GROUP (NOTES 1, 2) ...
Page 5
... AC measurements assume RL = 500 , CL = 50pF, Input 3ns, VIL = GND, VIH = 3V. 3. For functional tests VO 4.0V is recognized as a logic “1”, and VO TABLE 5. BURN-IN AND OPERATING LIFE TEST, DELTA PARAMETERS (+25 PARAMETER ICC IOL/IOH IOZL/IOZH Specifications HCTS374MS (NOTES 1, 2) CONDITIONS TEMPERATURE 0.5V is recognized as a logic “0”. GROUP B SUBGROUP DELTA LIMIT ...
Page 6
... Each pin except VCC and GND will have a resistor of 680 OPEN 12, 15, 16, 19 NOTE: Each pin except VCC and GND will have a resistor of 47K Group E, Subgroup 2, sample size is 4 dice/wafer 0 failures. Specifications HCTS374MS TABLE 6. APPLICABLE SUBGROUPS METHOD GROUP A SUBGROUPS 100%/5004 ...
Page 7
... Variables Data (All Delta operations). Data is identified by serial number. Data header includes lot number and date of test. • The Certificate of Conformance is a part of the shipping invoice and is not part of the Data Book. The Certificate of Conformance is signed by an authorized Quality Representative. HCTS374MS 100% Interim Electrical Test 1 (T1) 100% Delta Calculation (T0-T1) 100% Static Burn-In 2, Condition hrs ...
Page 8
... CP 10% 10% TW TPLH VS Qn FIGURE 1. CLOCK TO OUTPUT DELAYS AND CLOCK PULSE WIDTH TTLH VOH 80% 20% OUTPUT VOL FIGURE 3. OUTPUT TRANSITION TIME AC Load Circuit HCTS374MS INPUT LEVEL TH(L) TPHL TSU( FIGURE 2. DATA SET-UP AND HOLD TIMES PARAMETER VCC TTHL 80% VIH 20% ...
Page 9
... VIH INPUT VS VIL TPHZ VOH VW OUTPUT VOZ THREE-STATE HIGH VOLTAGE LEVELS PARAMETER HCTS VCC 4.50 VIH 3.00 VS 1.30 VT 1.30 VW 3.60 VIL 0 GND 0 HCTS374MS Three-State Low Load Circuit TPLZ VW UNITS Three-State High Load Circuit DUT TPZH CL = 50pF 500 UNITS ...
Page 10
... D1 (4) Q1 (5) Q2 (6) D2 (7) (8) D3 NOTE: The die diagram is a generic plot from a similar HCS device intended to indicate approximate die size and bond pad location. The mask series for the HCTS374 is TA14404A. HCTS374MS HCTS374MS Q0 OE VCC Q7 (2) (1) (20) (19) (9) (10) ...
Page 11
... For information regarding Intersil Corporation and its products, see web site http://www.intersil.com Sales Office Headquarters NORTH AMERICA Intersil Corporation P. O. Box 883, Mail Stop 53-204 Melbourne, FL 32902 TEL: (321) 727-9207 FAX: (321) 724-7240 HCTS374MS EUROPE Intersil SA Mercure Center 100, Rue de la Fusee 1130 Brussels, Belgium TEL: (32) 2.724.2111 FAX: (32) 2.724.22.05 ...