hcts191ms Intersil Corporation, hcts191ms Datasheet
hcts191ms
Related parts for hcts191ms
hcts191ms Summary of contents
Page 1
... Carry output. The HCTS191MS utilizes advanced CMOS/SOS technology to achieve high-speed operation. This device is a member of radiation hardened, high-speed, CMOS/SOS Logic Family. The HCTS191MS is supplied lead Ceramic flatpack (K suffi SBDIP Package (D suffix). Ordering Information PART NUMBER TEMPERATURE RANGE ...
Page 2
FF0 FF1 FF2 ...
Page 3
... VCC = 4.5V, VIH = 2.25V, Functional Test VIL = 0.8V (Note 2) NOTES: 1. All voltages reference to device GND. 2. For functional tests VO 4.0V is recognized as a logic “1”, and VO Specifications HCTS191MS Reliability Information Thermal Resistance SBDIP Package 10mA Ceramic Flatpack Package . . . . . . . . . . . 25mA Maximum Package Power Dissipation at +125 SBDIP Package ...
Page 4
... U TPLH VCC = 4.5V TPHL VCC = 4. TPLH VCC = 4.5V TPHL VCC = 4.5V NOTES: 1. All voltages referenced to device GND measurements assume RL = 500 , CL = 50pF, Input 3ns, VIL = GND, VIH = 3V. Specifications HCTS191MS GROUP (NOTES SUB- CONDITIONS GROUPS TEMPERATURE 9 10, 11 +125 9 10, 11 +125 ...
Page 5
... The parameters listed in Table 3 are controlled via design or process parameters. Min and Max Limits are guaranteed but not directly tested. These parameters are characterized upon initial design release and upon design changes which affect these characteristics. Specifications HCTS191MS CONDITIONS NOTES ...
Page 6
... AC measurements assume RL = 500 , CL = 50pF, Input 3ns, VIL = GND, VIH = 3V. 3. For functional tests VO 4.0V is recognized as a logic “1”, and VO TABLE 5. BURN-IN AND OPERATING LIFE TEST, DELTA PARAMETERS (+25 PARAMETER ICC IOL/IOH Specifications HCTS191MS (NOTES 1, 2) CONDITIONS TEMPERATURE 0.5V is recognized as a logic “0”. GROUP B SUBGROUP ...
Page 7
... Each pin except VCC and GND will have a resistor of 1k OPEN 12, 13 NOTE: Each pin except VCC and GND will have a resistor of 47K E, Subgroup 2, sample size is 4 dice/wafer 0 failures. Specifications HCTS191MS TABLE 6. APPLICABLE SUBGROUPS METHOD GROUP A SUBGROUPS 100%/5004 ...
Page 8
... Variables Data (All Delta operations). Data is identified by serial number. Data header includes lot number and date of test. • The Certificate of Conformance is a part of the shipping invoice and is not part of the Data Book. The Certificate of Conformance is signed by an authorized Quality Representative. HCTS191MS 100% Interim Electrical Test 1 (T1) 100% Delta Calculation (T0-T1) 100% Static Burn-In 2, Condition hrs ...
Page 9
... For information regarding Intersil Corporation and its products, see web site http://www.intersil.com Sales Office Headquarters NORTH AMERICA Intersil Corporation P. O. Box 883, Mail Stop 53-204 Melbourne, FL 32902 TEL: (321) 724-7000 FAX: (321) 724-7240 HCTS191MS AC Load Circuit DUT TPHL CL = 50pF RL = 500 TTHL 80% ...
Page 10
... Metallization Mask Layout Q0 (3) CE (4) U/D (5) Q2 (6) Q3 (7) NOTE: The die diagram is a generic plot from a similar HCS device intended to indicate approximate die size and bond pad location. The mask series for the HCTS191 is TA14447A. HCTS191MS HCTS191MS Q1 P1 VCC (2) (1) (16) (8) (9) ...