h3fa-sbu Omron Corporation, h3fa-sbu Datasheet
h3fa-sbu
Related parts for h3fa-sbu
h3fa-sbu Summary of contents
Page 1
... Mountable on a 1-inch pitch rack. (H 19.5 × W 36.9 × D 17.75 mm) Model Number Structure Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 2 for availability. H3FA Time-limit contact None: Contact outputs (SPST-NO + SPST-NC) ...
Page 2
... H3FA H3FA-BU H3FA-SAU H3FA-SBU Solid-state output H3FA-BU --- --- 5DC --- --- --- H3FA-BU --- --- 12DC H3FA-BU --- --- 24DC --- H3FA-SAU H3FA-SBU 5/6DC 5/6DC --- H3FA-SAU H3FA-SBU 12/24DC 12/24DC Time setting range 0 0 min min 0 0 min min 2 ...
Page 3
... H3FA H3FA-SA/ H3FA-SB H3FA-SAU/ H3FA-SBU 90% to 110% of rated supply voltage 85% to 110% of rated supply voltage approx approx. 100 mW approx. 240 mW 3 ...
Page 4
... For the internal variable resistor Power supply Reset circuit Reset input Time range selector H3FA-AU, H3FA-BU, H3FA-SAU, H3FA-SBU Contact Output For the external resistor For the internal variable resistor Power supply Reset circuit Start circuit ■ Rated Time and Terminal Connections ...
Page 5
... Timing Charts and External Connections Note: Do not apply voltage to any terminals other than the power supply terminals. Otherwise, the internal circuits may be damaged. H3FA-A, H3FA-B, H3FA-SA, H3FA-SB Standard Operation (ON-delay operation) When the power is turned ON and the set time has elapsed, an output is produced ...
Page 6
... H3FA-AU, H3FA-BU, H3FA-SAU, H3FA-SBU One-shot Output Operation Turn ON the power and apply a start input (short terminals 6 and 1). (Power turns ON when power terminals 1 and 24 are shorted or when terminals 13 and 15 are shorted when using a 12/24 V DC- operated model with power supply.) An output is produced immediately and is reset when the set time has elapsed ...
Page 7
... Refer to the following characteristics diagrams when using an external resistor. • Use an external resistor rated at about 0.1 W/1 MΩ for H3FA-A, -SA, -AU, and -SAU or 0.1 W/3 MΩ for H3FA-B, -SB, -BU, and - SBU. • Do not run leads parallel to power lines and keep the leads shorter than minimize the effects of external noise. • ...
Page 8
... Note: All units are in millimeters unless otherwise indicated. H3FA-A, H3FA-B, H3FA-SA, H3FA-SB Applicable Connecting Socket Standard 24-pin IC socket can be used to mount the Timer. H3FA-AU, H3FA-BU, H3FA-SAU, H3FA-SBU Applicable Connecting Socket Standard 24-pin IC socket can be used for mounting the Timer. H3FA Mounting holes (Top view) H3FA-A/-B Twelve, 1 ...
Page 9
... Do not operate the H3FA in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. • Do not use the H3FA in locations subject to vibrations or shock. Extended use in such locations may result in damage due to stress. • Do not use the H3FA in locations subject to excessive dust, corrosive gas, or direct sunlight ...
Page 10
... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2008 All Right Reserved. 2008.12 ...