twr-3.3 C&D Technologies., twr-3.3 Datasheet
twr-3.3
Related parts for twr-3.3
twr-3.3 Summary of contents
Page 1
... Peak-to-peak output ripple/noise is typically 80-100mV at full load. Efficiencies range up to 87%. The TWR 22W series outputs will limit their current if driven to overload and may be short circuited indefinitely without damage. The inputs will shut down if input voltage is either over or under limits or has reversed input voltage ...
Page 2
... Performance Specifications and Ordering Guide V I OUT OUT Model Volts Amps 3.3 4 TWR-3.3/4-12/300-D12-C ±12 0.3 3.3 4 TWR-3.3/4-12/300-D24-C ±12 0.3 3.3 4 TWR-3.3/4-12/300-D48N-C ±12 0.3 3.3 4 TWR-3.3/4-15/250-D12-C ±15 0.25 3.3 4 TWR-3.3/4-15/250-D24-C ±15 0.25 3.3 4 TWR-3.3/4-15/250-D48N-C ±15 0. TWR-5/3-12/300-D12-C ±12 0 TWR-5/3-12/300-D24-C ±12 0 TWR-5/3-12/300-D48N-C ±12 0 TWR-5/3-15/250-D12-C ±15 0. TWR-5/3-15/250-D24-C ± ...
Page 3
... Remove overload for recovery. Short-Circuit Current: 3. Output 2 Amps maximum ±12V or ±15V Outputs 1 Amp maximum www.murata-ps.com Triple Output/TWR Models Isolated, High Reliability 1" x 2" DC/DC Converters Short Circuit Duration (no damage) Overvoltage Protection: 3. Output ±12V or ±15V Outputs Dynamic Load Response (50-100% loadstep) 3. Output ± ...
Page 4
... Ripple Current and Output Noise All TWR converters are tested and specified for input reflected ripple cur- rent (also called Back Ripple Current) and output noise using specified filter components and test circuit layout as shown in the figures below. Input capacitors must be selected for low ESR, high AC current-carrying capabil- ity at the converter’ ...
Page 5
... Contact DATEL if you need further advice on these topics. Remote On/Off Control The TWR models include an input pin which can turn on or shut off the converter by remote signal. For positive logic models (no model number suffix), if this pin is left open, the converter will always be enabled as long as proper input power is present ...
Page 6
... Most PWM controllers, including those on the TWR’s, will tolerate opera- tion up to about +100 degrees Celsius doubt, attach a thermal sensor to the package near the output components and measure the surface temperature after allowing a proper warm-up period ...
Page 7
... Triple Output/TWR Models Isolated, High Reliability 1" x 2" DC/DC Converters Typical Performance Curves for TWR Series Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_TWR22.B02 Page ...
Page 8
... Triple Output/TWR Models Isolated, High Reliability 1" x 2" DC/DC Converters Typical Performance Curves for TWR Series Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 MDC_TWR22.B02 Page ...
Page 9
... Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com Japan: ISO 9001 REGISTERED 06/12/08 China: © 2008 Murata Power Solutions, Inc. Triple Output/TWR Models Note: Some model number combinations may not be available. Contact Murata Power Solutions. Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0 01, email: france@murata-ps ...