h5cx-l8sd Omron Corporation, h5cx-l8sd Datasheet - Page 5

no-image

h5cx-l8sd

Manufacturer Part Number
h5cx-l8sd
Description
Digital Timer
Manufacturer
Omron Corporation
Datasheet
■ Characteristics
Note 1. The values are based on the set value.
Accuracy of operating time
and setting error (including
temperature and voltage in-
fluences) (See note 1.)
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Life expectancy
Approved safety standards
(See notes 3 and 4.)
EMC
Degree of protection
Weight
2. The value is applied for a minimum pulse width of 1 ms.
3. To meet UL listing requirements with H5CX-L8@/-A11@ models, an OMRON P2CF-08-@ or P3G-08 Socket must be mounted on the Timer.
4. The Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter are necessary to ensure IP66, NEMA4, and UL Type 4X water-
Otherwise, H5CX-L8@/-A11@ models are considered to meet UL508 recognition requirements.
proofing between the H5CX and installation panel.
Item
Power-ON start: ±0.01% ±50 ms max. Rated against set value
Signal start: ±0.005% ±30 ms max. Rated against set value
Signal start for transistor output model: ±0.005% ±3 ms max. (See note 2.)
If the set value is within the sensor waiting time at startup the control output of the H5CX will not turn ON until the
sensor waiting time passes.
100 MΩ min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and
between non-continuous contacts
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
1,000 VAC (for H5CX-@SD), 50/60 Hz for 1 min between control output, power supply, and input circuit (2,000 VAC
for models other than H5CX-@SD)
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC
1.5 kV for 24 VAC/12 to 24 VDC
±1.5 kV (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator
(pulse width: 100 ns/1 µs, 1-ns rise)
Destruction: 15 kV
Malfunction: 8 kV
Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions, 2 hours each
Malfunction: 10 to 55 Hz with 0.35-mm single amplitude each in three directions, 10 min each
Destruction: 294 m/s
Malfunction: 196 m/s
Mechanical: 10,000,000 operations min. (under no load at 18,000 operations/h)
Electrical:
UL508/Listing, UL50 Type 4X for indoor use (enclosure rating), CSA C22.2 No. 14, conforms to EN61812-1 (Pollution
degree 2/overvoltage category III)
Conforms to VDE0106/P100 (finger protection).
(EMI)
Emission Enclosure:
Emission AC mains:
(EMS)
Immunity ESD:
Immunity RF-interference:
Immunity Conducted
Disturbance:
Immunity Burst:
Immunity Surge:
Immunity Voltage Dip/Interruption EN61000-4-11: 0.5 cycle, 100% (rated voltage)
Panel surface: IP66 and NEMA4 (indoors), and UL Type 4X (indoors) (See note 4.)
H5CX-A@: Approx. 135 g, H5CX-A11@/-L8@: Approx. 105 g
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
See Life-test Curve on page 6.
2
2
each in three directions
each in three directions
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
EN61000-4-5:
EN61812-1
EN61000-4-2:
EN61000-4-3:
EN61000-4-6:
EN61000-4-4:
H5CX-A@/-A11@/-L8@
6 kV contact discharge (level 2)
8 kV air discharge (level 3)
10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3);
1 kV I/O signal-line (level 4)
1 kV line to lines (power and output lines) (level 3);
2 kV line to ground (power and output lines) (level 3)
H5CX-A/-L
5

Related parts for h5cx-l8sd