h3ca-8 Omron Corporation, h3ca-8 Datasheet

no-image

h3ca-8

Manufacturer Part Number
h3ca-8
Description
Solid-state Timer
Manufacturer
Omron Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H3CA-8
Manufacturer:
OMRON
Quantity:
2 000
Part Number:
h3ca-8-AC100/110/120
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Part Number:
h3ca-8H
Manufacturer:
OMRON
Quantity:
2 000
Part Number:
h3ca-8H AC100/110/120
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Part Number:
h3ca-8H-AC220V
Manufacturer:
OMRON
Quantity:
12 000
DIN-sized (48 x 48, 45 x 75 mm) Timer with
Digital Setting and LCD Display
• Dual power supplies for free AC/DC.
• Eight operation modes selectable with one unit.
• Any desired time can be set digitally within a range from 0.1
• Four external signal inputs.
• ON/OFF indicator for control output and bar indicator for
• Conforms to UL, CSA, and CE marking.
Ordering Information
Note: 1. Specify both the model number and supply voltage when ordering for the H3CA-8H and H3CA-8.
■ Accessories (Order Separately)
Note: Track mounted socket can be used as a front connecting socket.
Specifications
■ Time Ranges
A desired time can be set within a range of 0.1 s to 9,990 hrs by combining the three thumbwheel switch modules for time setting and one module
for time unit selection.
Time unit
Time range
Time-limit operation/self-
resetting/external
resetting (see note 2)
Time-limit operation/
self-resetting
H3CA-A
H3CA-8H/H3CA-8
seconds to 9,990 hrs.
remaining time.
Solid-state Timer
H3CA
Operation/resetting
2. The operation/resetting system depends on the selected operation mode. For details, see “Timing Chart”.
3. The 8 operation modes are as follows:
system
Timer
A: ON-delay operation
B: Repeat cycle operation
C: Signal ON/OFF-delay operation (1)
D: Signal OFF-delay operation (1)
1 to 999 (3 digits)
8 operation modes
(selectable)
(see note 3)
ON-delay operation 8-pin round socket DPDT
Operation mode
P2CF-11
P2CF-08
Track mounted socket
0.1 s
11-pin round socket SPDT
Front screw
(See note.)
Terminal
1 s
SPDT
Time-limit
contact
0.1 min
PL11
PL08
Solder terminal
---
---
SPDT
Instantaneous
1 min
contact
E: Interval operation
F: One-shot and flicker operation
G: Signal ON/OFF-delay operation (2)
H: Signal OFF-delay operation (2)
Back connecting socket
0.1 hrs
H3CA-A
H3CA-FA
H3CA-8
H3CA-8H
track mounting
mounting/
P3GA-11
P3G-08
Surface
1 hr
Screw terminal
Mounting
CSM_H3CA_DS_E_2_1
H3CA-A
---
H3CA-8
H3CA-8H
Flush mounting
10 hrs
1

Related parts for h3ca-8

h3ca-8 Summary of contents

Page 1

... ON-delay operation 8-pin round socket DPDT self-resetting Note: 1. Specify both the model number and supply voltage when ordering for the H3CA-8H and H3CA-8. 2. The operation/resetting system depends on the selected operation mode. For details, see “Timing Chart”. 3. The 8 operation modes are as follows: ...

Page 2

... Influence of temperature ±0.5% ±0.05 s max. Setting error Reset time H3CA-A/-FA: 0.5 s max. H3CA-8H/-8: 0.1 s max. Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts and between contact and control circuit) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) ...

Page 3

... Control output ON/OFF indication Remaining time elapses, the remaining time is indicated by a pattern of bars in tenth of 1/10 of the set time. Set Time Indicators (3 Digits) Operation Mode Selector (Fixed to "A" in H3CA-8H) A: ON-delay operation B: Flicker operation C: Signal ON/OFF-delay operation (1) D: Signal OFF-delay operation (1) E: Interval operation ...

Page 4

... Operation ■ Timing Chart H3CA-A (FA) ON-delay Operation (A Mode) Signal Start t: Set time; t-a: Time within the set time Note: The minimum signal input time is 0.05 s. Flicker Operation (B Mode) Signal Start t: Set time; t-a: Time within the set time Note: The minimum signal input time is 0.05 s. ...

Page 5

... Signal OFF-delay Operation 1 (D Mode) t: Set time; t-a: Time within the set time t: Set time Power-ON Start/Power-OFF Reset t: Set time; t-a: Time within the set time Note: The minimum signal input time is 0.05 s. Signal ON/OFF-delay Operation 2 (H Mode) t-a t: Set time; t-a: Time within the set time H3CA 5 ...

Page 6

... A (ON-delay operation). 2. The set time is the sum of t and t 1 H3CA-8H How to Use Check Signal Input If a check signal is input to the timer during the lapse of a set time, the remaining set time will become 0 and the timer will enter the next control state ...

Page 7

... Terminal Arrangement Mounting Holes (Top View) Note: P2CF-08 can be used as a front connecting socket. H3CA Two,M4 or 4.5 dia. holes Note: When mounting two or more timers in line, dimension L between two adjacent timers should min. Mounting Height of Timer with Socket 108 ...

Page 8

... View) M3.5 Terminal Arrangement Mounting Holes (Bottom View) Two, 3.5 dia socket mounting holes Terminal Arrangement Mounting Holes (Bottom View) Two, 3.5 dia socket mounting holes H3CA Mounting Height of Timer with Socket 86.3 10.9 P3G-08 Mounting Height of Timer with Socket Hold-down clip 79.6 Y92H-1 ...

Page 9

... Y92A-48B Protective Cover attached, which must be taken into consideration before using the Y92A-48B Protective Cover. When attaching the Y92A-48A to the Timer to be panel-mounted, use the Y92F-30 Mounting Adapter along with the Timer. The Protective Cover cannot be, however, used for the H3CA-FA Series. H3CA 9 ...

Page 10

... Note: 1. *C: Check: 3-4 *G: Gate: 3-5 *S: Start: 3-6 *R: Reset: 3-7 2. Conventional time-limit contacts are symbolized as However, the contacts of H3CA-A are symbolized as because timer has 8 operation modes. ■ Input Connections Signal Inputs Connect the start input contact between terminals C and F, the reset input contact between terminals C and G, the gate input contact between terminals C and E, and the check input contact between terminals C and D ...

Page 11

... Note: Except for the power supply circuitry, avoid the laying of input signal wires in parallel or in the same conduit with high-tension or power lines recommended to use shielded wires or wiring with independent metal conduits for the shortest possible distance. H3CA-8H (-) (+) H3CA-8 (-) (+) H3CA 11 ...

Page 12

... Application Examples Standard type H3CA is used for the following application examples. In the schematic diagrams, each thick the indicates the wiring necessary for selecting the desired operation mode. ON-delay Operation (A Mode) Power-ON Start/Power-OFF Reset (+) or (−) (+) or (−) Flicker Operation (B Mode) Power-ON Start/Power-OFF Reset (+) or (− ...

Page 13

... Interval Operation (E Mode) Power-ON Start/Power-OFF Reset One-shot and Flicker Operation (F Mode) Power-ON Start/Power-OFF Reset Signal Start/Signal Reset (+) or (−) (+) or (−) Signal Start/Signal Reset (+) or (−) (+) or (−) Signal OFF-delay Operation 2 (H Mode) Signal/Instantaneous Operation/Time-limit Reset (+) or (−) (+) or (−) H3CA (+) or (−) (+) or (−) (+) or (−) (+) or (−) (+) or (−) (+) or (−) 13 ...

Page 14

... The power supply connections to the H3CA-A and H3CA-FA can be made without regard to polarity for both AC and DC power supplies; just connect to the specified terminals (2 and 10 and A2). When connecting a DC power supply to the H3CA-8 or H3CA-8H, however, the polarity must be connected as indicated. Although there is a wide range of power connectable to the H3CA-A ...

Page 15

... Input terminal Circuit Isolation transformer is required. A transformer is not used in the power supplies for the H3CA-A and H3CA-FA. You can therefore receive an electrical shock by touching the input terminals when the power supply voltage is being applied. Take adequate precautions to protect against electrical shock. ...

Page 16

... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2008 All Right Reserved. 2008.11 ...

Related keywords