sky65009-21 Skyworks Solutions, Inc., sky65009-21 Datasheet - Page 7

no-image

sky65009-21

Manufacturer Part Number
sky65009-21
Description
Sky65009 250 ? 2500 Mhz Linear Power Amplifier Driver
Manufacturer
Skyworks Solutions, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SKY65009-21
Manufacturer:
Skyworks
Quantity:
1 400
Evaluation Board Description
The Skyworks SKY65009 Evaluation Board is used to test the
performance of the SKY65009 power amplifier driver. An
assembly drawing for the Evaluation Board is shown in Figure 11
and the layer detail is provided in Figure 12.
Circuit Design Configurations
The following design considerations are general in nature and
must be followed regardless of final use or configuration.
1. Paths to ground should be made as short as possible.
2. The ground pad of the SKY65009 power amplifier has special
NOTE: Junction temperature (T
J1 (RF In)
electrical and thermal grounding requirements. This pad is the
main thermal conduit for heat dissipation. Since the circuit
board acts as the heat sink, it must shunt as much heat as
possible from the amplifier. As such, design the connection to
the ground pad to dissipate the maximum wattage produced
to the circuit board. Multiple vias to the grounding layer are
required.
poor connection to the slug and ground. This reduces the
lifetime of the device.
200404C • Skyworks Proprietary and Confidential information • Products and Product Information are Subject to Change Without Notice • November 2, 2006
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
J
) of the device increases with a
Figure 11. Evaluation Board Assembly Drawing
C1
C2
C3
JP1
R1
A suggested matching circuit is shown in Figure 13 with
component values listed in Table 5 (SKY65009-21) and Table 6
(SKY65009-70LF).
Testing Procedure
Use the following procedure to set up the SKY65009 Evaluation
Board for testing:
1. Connect a 5 V supply to VCC. If available, enable the current
2. Connect a signal generator to the RF signal input port. Set it to
3. Connect a spectrum analyzer to the RF signal output port.
4. Enable the power supply.
5. Enable the RF signal.
6. Take measurements.
CAUTION: If any of the output signals exceed the rated
L5
C7
limiting function of the power supply to 240 mA.
the desired RF frequency at a power level of –15 dBm or less
to the Evaluation Board but do NOT enable the RF signal.
C4
C5
C8
C9
C6
maximum values, the SKY65009 Evaluation Board
can be permanently damaged.
PRELIMINARY DATA SHEET • SKY65009 PA DRIVER
J2 (RF Out)
S708
7

Related parts for sky65009-21