dc025 Lineage Power, dc025 Datasheet - Page 2

no-image

dc025

Manufacturer Part Number
dc025
Description
Dc025 Dual-output-series Power Modules
Manufacturer
Lineage Power
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
dc025AB-M
Manufacturer:
Lucent
Quantity:
26
Part Number:
dc025AB-M
Manufacturer:
LAMBDA
Quantity:
1 000
Part Number:
dc025AB-M
Manufacturer:
SANREX
Quantity:
20 000
Part Number:
dc025AB-M
Quantity:
55
Part Number:
dc025ACL-M
Manufacturer:
LUCENT
Quantity:
26
Part Number:
dc025ACL-M
Quantity:
292
Part Number:
dc025ACL-M
Manufacturer:
SANREX
Quantity:
20 000
Part Number:
dc025ACL-M
Quantity:
55
Part Number:
dc025ACL8-M
Manufacturer:
LUCENT
Quantity:
228
18 Vdc to 36 Vdc Input; 25 W
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical Specifications
Note: Two pinouts are available for the DC025 Dual-Output-Series Power Modules. The DC025AJ-M, AB-M,
Unless otherwise indicated, specifications apply to all modules over all operating input voltage, resistive load, and
temperature conditions.
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow, dc fuse with a maximum rating of 5 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
2
Input Voltage (continuous)
I/O Isolation Voltage:
Operating Case Temperature
Storage Temperature
Operating Input Voltage
Maximum Input Current
Inrush Transient
Input Reflected-ripple Current, Peak-to-Peak
Input Ripple Rejection (120 Hz)
(V
(5 Hz to 20 MHz, 12 µH source impedance;
T
Considerations section.)
dc
Transient (1 minute)
C
I
= 0 V to 36 V; I
= 25 °C; see Figure 11 and Design
BK-M, and CL-M Power Modules, which have both positive and negative outputs, have a common output
ground pin (pinout A). The DC025AA-M, AB-M, AF-M, BB-M, and CC-M Power Modules, which have dual
positive outputs, have separate output ground pins (pinout B). See Outline Diagrams section.
Parameter
O
Parameter
= I
O
,
max
; see Figure 1.)
Symbol
I
I, max
V
i
2
Symbol
t
I
T
T
V
stg
C
I
Min
18
Min
–40
–55
Typ
28
25
60
Max
500
850
100
125
50
Max
3.0
0.8
36
Lineage Power
March 2008
Unit
mAp-p
°C
°C
V
V
V
Unit
Vdc
A
dB
A
2
s

Related parts for dc025