ltm4601ahv Linear Technology Corporation, ltm4601ahv Datasheet - Page 12

no-image

ltm4601ahv

Manufacturer Part Number
ltm4601ahv
Description
12a, 28vin Dc/dc ?module With Pll, Output Tracking And Margining
Manufacturer
Linear Technology Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ltm4601ahvEY#PBF
Manufacturer:
LT
Quantity:
218
Part Number:
ltm4601ahvIV#PBF
Manufacturer:
LT
Quantity:
560
Part Number:
ltm4601ahvIV#PBF
Manufacturer:
Linear Technology
Quantity:
135
Part Number:
ltm4601ahvIY#PBF
Manufacturer:
LT
Quantity:
827
Part Number:
ltm4601ahvIY#PBF
Manufacturer:
LINEAR
Quantity:
20 000
Part Number:
ltm4601ahvMPV#PBF
Manufacturer:
MSC
Quantity:
4 300
Part Number:
ltm4601ahvMPY
Manufacturer:
LT/凌特
Quantity:
20 000
Part Number:
ltm4601ahvY
Manufacturer:
LINEAR
Quantity:
20 000
LTM4601AHV
APPLICATIONS INFORMATION
Multiphase operation with multiple LTM4601AHV devices
in parallel will lower the effective output ripple current due
to the interleaving operation of the regulators. For example,
each LTM4601AHV’s inductor current of a 12V to 2.5V
multiphase design can be read from the Inductor Ripple
Current versus Duty Cycle graph (Figure 3). The large
ripple current at low duty cycle and high output voltage
12
12
10
8
6
4
2
0
0
Figure 3. Inductor Ripple Current vs Duty Cycle
Figure 4. Normalized Output Ripple Current vs Duty Cycle, Dlr = V
20
DUTY CYCLE (V
40
OUT
1.00
0.95
0.90
0.85
0.80
0.75
0.70
0.65
0.60
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
/V
0
IN
0.1 0.15 0.2 0.25
60
)
4601AHV F03
80
0.3
2.5V OUTPUT
5V OUTPUT
1.8V OUTPUT
1.5V OUTPUT
1.2V OUTPUT
3.3V OUTPUT WITH
130k ADDED FROM
V
5V OUTPUT WITH
100k ADDED FROM
f
SET
OUT
0.35
TO GND
TO f
SET
0.4 0.45 0.5 0.55 0.6 0.65 0.7 0.75 0.8 0.85 0.9
DUTY CYCLE (V
can be reduced by adding an external resistor from f
ground which increases the frequency. If the duty cycle is
DC = 2.5V/12V = 0.21, the inductor ripple current for 2.5V
output at 21% duty cycle is ~6A in Figure 3.
Figure 4 provides a ratio of peak-to-peak output ripple cur-
rent to the inductor current as a function of duty cycle and
the number of paralleled phases. Pick the corresponding
duty cycle and the number of phases to arrive at the correct
output ripple current ratio value. If a 2-phase operation is
chosen at a duty cycle of 21%, then 0.6 is the ratio. This
0.6 ratio of output ripple current to inductor ripple of 6A
equals 3.6A of effective output ripple current. Refer to Ap-
plication Note 77 for a detailed explanation of output ripple
current reduction as a function of paralleled phases.
The output voltage ripple has two components that are
related to the amount of bulk capacitance and effective
series resistance (ESR) of the output bulk capacitance.
Therefore, the output voltage ripple can be calculated with
the known effective output ripple current. The equation:
ΔV
O
/V
OUT(P-P)
IN
)
O
T/L
≈ (ΔI
I
, Dlr = Each Phase’s Inductor Current
L
/(8 • f • m • C
1-PHASE
2-PHASE
3-PHASE
4-PHASE
6-PHASE
4601AHV F04
OUT
) + ESR • ΔI
L
), where