Transmitter Output Return Loss Measurements
The following measurements were made with a Wandel
and Goltermann SNA--2 Network Analyzer equipped with
an RFZ--1 75W Return Loss Bridge. A 75W to 120W
impedance matching transformer was used to make the
120W measurement. A network analyzer calibration run
subtracted out the effects of this transformer.
Test Conditions:
D Output transformer ratio was 1:2.
D Transmitter series resistors (R3 and R4 in Figure 1)
D Device was powered from a 3.3V source, transmitter
Notes:
XRT5897
fb = 2048KHz
This data shows that the XRT5897 is fully compliant with the ETSI Output Return Loss Specification for E1 operation with either
75W or 120W loads.
were 9.1W.
was enabled, and no output data was present.
Rev. 1.11
Frequency
Specified
0.025 fb
0.05 fb
1.5 fb
Table 5. Transmitter Output Return Loss Measurements
Frequency
(KHz)
102.4
3072
51.2
ETSI Spec.
(Min. dB)
6
8
8
16
This configuration was used for both 75W and 120W
measurements. The only change was the termination
resistance provided by the return loss bridge.
Test Results:
Table 5 compares measured output return loss with
requirements in ETSI FINAL DRAFT prETS 300 166,
June 1993. These results show that measured return loss
is mainly determined by the characteristics of the output
transformer. This is particularly evident for the 120W load
where the measured result is better than the calculated
value.
Meas. Value (dB)
75W Load
22.6
22.6
18.0
Meas. Value (dB)
120W Load
15.4
15.7
14.6