xr16l570il32 Exar Corporation, xr16l570il32 Datasheet - Page 33

no-image

xr16l570il32

Manufacturer Part Number
xr16l570il32
Description
Smallest 1.62v To 5.5v Uart With 16-byte Fifo And Powersave
Manufacturer
Exar Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
xr16l570il32-F
Manufacturer:
CYPRESS
Quantity:
101
Part Number:
xr16l570il32-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
xr16l570il32-F
Quantity:
55 230
Company:
Part Number:
xr16l570il32-F
Quantity:
55 230
Company:
Part Number:
xr16l570il32TR-F
Quantity:
6 000
REV. 1.0.1
EFR[5]: Special Character Detect Enable
EFR[6]: Auto RTS Flow Control Enable
RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is
selected, an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and
RTS de-asserts to a logic 1 at one trigger level above the programmed trigger level. RTS# will return to a logic
0 when FIFO data falls below one trigger level below the programmed trigger level. The RTS# output must be
asserted (logic 0) before the auto RTS can take effect. RTS# pin will function as a general purpose output
when hardware flow control is disabled.
EFR[7]: Auto CTS Flow Control Enable
Automatic CTS Flow Control.
These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2.
For more details, refer to
4.16
Logic 0 = Special Character Detect Disabled (default).
Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with
data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set
to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If
flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= ‘10’) then flow control and special character work
normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= ‘01’) then flow control works
normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character
interrupt, if enabled via IER bit-5.
Logic 0 = Automatic RTS flow control is disabled (default).
Logic 1 = Enable Automatic RTS flow control.
Logic 0 = Automatic CTS flow control is disabled (default).
Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts to logic
1. Data transmission resumes when CTS# returns to a logic 0.
Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Write Only
“Section 2.15, Auto Xon/Xoff (Software) Flow Control” on page
SMALLEST 1.62V TO 5.5V UART WITH 16-BYTE FIFO AND POWERSAVE
33
15.
XR16L570

Related parts for xr16l570il32