acpl-p456 Avago Technologies, acpl-p456 Datasheet - Page 5

no-image

acpl-p456

Manufacturer Part Number
acpl-p456
Description
Intelligent Power Module And Gate Drive Interface Optocouplers
Manufacturer
Avago Technologies
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
acpl-p456-000E
Manufacturer:
Avago Technologies
Quantity:
135
Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics* (ACPL-P456/W456 Option 060)
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
Table 2. Insulation and Safety Related Specifications

Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 450 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V
Partial discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage t
Safety-limiting values – maximum values
allowed in the event of a failure.
Case Temperature
Input Current
Output Power
Insulation Resistance at T
Parameter
Minimum External Air Gap
(External Clearance)
Minimum External Tracking
(External Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Minimum Internal Tracking
(Internal Creepage)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
IORM
IORM
DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
x 1.875=V
x 1.5=V
PR
, Type and Sample Test, t
PR
, 100% Production Test with t
ini
S
, V
= 10 sec)
IO
= 500 V
Symbol
L(101)
L(102)
CTI
m
=60 sec,
ACPL-P456
m
>175
0.08
7.0
8.0
NA
IIIa
=1 sec,
ACPL-W456
>175
0.08
8.0
8.0
NA
IIIa
Symbol
V
V
V
V
T
I
P
R
S, INPUT
S
IORM
PR
PR
IOTM
S, OUTPUT
S
Units
mm
mm
mm
mm
V
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
Measured from input terminals to output
terminals, along internal cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
ACPL-W456
I – IV
I – IV
I – III
I – III
I – II
55/100/21
2
1140
2137
1710
6000
175
230
600
>10
9
ACPL-P456
I – IV
I – IV
I – III
I – III
55/100/21
2
891
1670
1336
6000
175
230
600
>10
9
Unit
V
V
V
V
°C
mA
mW
W
peak
peak
peak
peak