s-93c46a Seiko Instruments Inc., s-93c46a Datasheet - Page 39

no-image

s-93c46a

Manufacturer Part Number
s-93c46a
Description
Cmos Serial E2prom
Manufacturer
Seiko Instruments Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s-93c46aDFJ
Manufacturer:
SEK
Quantity:
2 000
Part Number:
s-93c46aDFJ
Manufacturer:
SEK
Quantity:
1 000
Part Number:
s-93c46aDFJ
Manufacturer:
SEIKO
Quantity:
1 803
Part Number:
s-93c46aDFJ
Manufacturer:
SEIKO
Quantity:
20 000
Part Number:
s-93c46aDFJ-TB
Manufacturer:
SEIKO
Quantity:
1 803
Part Number:
s-93c46aDFJ-TB
Manufacturer:
SEIKO
Quantity:
1 533
Part Number:
s-93c46aDFJ-TB
Manufacturer:
SEIKO
Quantity:
20 000
Part Number:
s-93c46aDFJ-TB(93C46DV8Y)
Manufacturer:
S
Quantity:
800
Part Number:
s-93c46aDFJ-TB-G
Manufacturer:
SII/精工
Quantity:
20 000
Part Number:
s-93c46aDFJ-TB-S
Manufacturer:
SEIKO
Quantity:
1 533
Part Number:
s-93c46aDFJ-TB-S
Manufacturer:
SEK
Quantity:
8 000
Part Number:
s-93c46aDFJ-TB-S
Manufacturer:
SEK
Quantity:
40 000
Part Number:
s-93c46aDFJ-TB-S
Manufacturer:
SEK
Quantity:
20 000
Company:
Part Number:
s-93c46aDFJ-TB-S
Quantity:
3 900
Part Number:
s-93c46aDFJ-V
Manufacturer:
SII/精工
Quantity:
20 000
Part Number:
s-93c46aDFJC-TB
Manufacturer:
RENESAS
Quantity:
1 832
<Remarks>
When the power-on clear circuit has finished initialization normally, the EEPROM enters a program-
disabled state. If the power-on clear circuit does not operate, the following situation is likely:
-
The following may prevent the power-on clear circuit from operating:
-
-
FAQ No.: 12011
In some cases, a previously entered command has been enabled. If, for example, a program-
enabled command has been enabled and the input terminal mistakenly recognizes a write command
due to extraneous noise while the next command is being entered, writing may be executed.
If the power lines of the microcomputer and EEPROM are separated from each other, and the output
terminals of the microcomputer and EEPROM are wired or connected to each other, there may be a
potential difference between the power lines of the EEPROM and microcomputer. If the voltage of
the microcomputer is higher, a current may flow from the output terminal of the microcomputer to the
power line of the EEPROM via a parasitic diode in the DO pin of the EEPROM. Therefore, the power
voltage of the EEPROM has an intermediate potential to prevent power-on from being cleared.
During an access to the EEPROM, the voltage may decrease due to power-off. Even if the
microcomputer has been reset due to a decrease in voltage, the EEPROM may malfunction if
EEPROM power-on clear operation conditions are not met. For the EEPROM power-on clear
operation conditions, see “Method for Activating the Power Voltage.”
1 0 0 m
100
1 0 m
1 0
1 m
1
1
10
Power-voltage activation time
100
1 m
1 0 m 1 0 0 m
Fig. 3 EEPROM initialization time
38
t
rise
(seconds)

Related parts for s-93c46a