m28w160c Numonyx, m28w160c Datasheet - Page 17
![no-image](/images/manufacturer_photos/0/4/484/numonyx_sml.jpg)
m28w160c
Manufacturer Part Number
m28w160c
Description
16 Mbit 1mb X16, Boot Block 3v Supply Flash Memory
Manufacturer
Numonyx
Datasheet
1.M28W160C.pdf
(50 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
m28w160cB-70N6
Manufacturer:
ST
Quantity:
8 360
Company:
Part Number:
m28w160cB-70N6
Manufacturer:
ST
Quantity:
52
Company:
Part Number:
m28w160cB-70N6
Manufacturer:
ST
Quantity:
3
Company:
Part Number:
m28w160cB-70ZB6
Manufacturer:
ST
Quantity:
52 675
Part Number:
m28w160cB-70ZB6
Manufacturer:
ST
Quantity:
20 000
Part Number:
m28w160cB-90N1
Manufacturer:
ST
Quantity:
20 000
Part Number:
m28w160cB-90N6
Manufacturer:
ST
Quantity:
20 000
Table 9. Block Lock Status
Table 10. Protection Status
Note: 1. The protection status is defined by the write protect pin and by DQ1 (‘1’ for a locked-down block) and DQ0 (‘1’ for a locked block)
Current State
2. All blocks are locked at power-up, so the default configuration is 001 or 101 according to WP status.
3. A WP transition to V
1,0,1
0,0,1
1,0,0
1,1,0
1,1,1
0,0,0
0,1,1
as read in the Read Electronic Signature command with A1 = V
Protection Status
(2)
(2)
(WP, DQ1, DQ0)
Current
Block Lock Configuration
Block is Locked-Down
Program/Erase
Block is Unlocked
Block is Locked
Allowed
IH
on a locked block will restore the previous DQ0 value, giving a 111 or 110.
yes
yes
yes
(1)
no
no
no
no
Item
Block Lock
Command
After
1,0,1
1,0,1
1,1,1
1,1,1
0,0,1
0,0,1
0,1,1
Block Unlock
IH
Command
and A0 = V
Next Protection Status
After
1,0,0
1,0,0
1,1,0
1,1,0
0,0,0
0,0,0
0,1,1
(WP, DQ1, DQ0)
Address
xx002
IL
.
M28W160CT, M28W160CB
After Block
Lock-Down
Command
1,1,1
1,1,1
1,1,1
1,1,1
0,1,1
0,1,1
0,1,1
(1)
1,1,1 or 1,1,0
DQ0=0
DQ0=1
DQ1=1
LOCK
WP transition
Data
After
0,0,0
0,0,1
0,1,1
0,1,1
1,0,0
1,0,1
17/50
(3)