24VL014
5.0
A control byte is the first byte received following the
Start condition from the master device (Figure 5-1).
The control byte consists of a four-bit control code; for
the 24VL014 this is set as ‘1010’ binary for read and
write operations. The next three bits of the control byte
are the Chip Select bits (A2, A1, A0). The Chip Select
bits allow the use of up to eight 24VL014 devices on the
same bus and are used to select which device is
accessed. The Chip Select bits in the control byte must
correspond to the logic levels on the corresponding A2,
A1 and A0 pins for the device to respond. These bits
are in effect the three Most Significant bits of the word
address.
For the SOT-23 package, the A2 pin is not connected.
During device addressing, the A2 chip select bit should
be set to logic ‘0’. Only four 24VL014 SOT-23 devices
can be connected to the same bus.
The last bit of the control byte defines the operation to
be performed. When set to a ‘1’, a read operation is
selected. When set to a ‘0’, a write operation is
selected. Following the Start condition, the 24VL014
monitors the SDA bus, checking the control byte being
transmitted. Upon receiving a ‘1010’ code and appro-
priate Chip Select bits, the slave device outputs an
Acknowledge signal on the SDA line. Depending on the
state of the R/W bit, the 24VL014 will select a read or
write operation.
DS22129A-page 8
DEVICE ADDRESSING
FIGURE 5-1:
5.1
The Chip Select bits A2, A1 and A0 can be used to
expand the contiguous address space for up to 8K bits
by adding up to eight 24VL014 devices on the same
bus. In this case, software can use A0 of the control
byte as address bit A7, A1 as address bit A8, and A2
as address bit A9. It is not possible to sequentially read
across device boundaries.
For the SOT-23 package, up to four devices can be
added for up to 4 Kbit of address space. In this case,
software can use A0 of the control byte as address bit
A7, and A1 as address bit A8. Bit A2 of the control byte
must always be set to logic ‘0’ for the SOT-23 package.
Start Bit
S
Contiguous Addressing Across
Multiple Devices
1
Control Code
0
Slave Address
1
CONTROL BYTE FORMAT
© 2009 Microchip Technology Inc.
0
Read/Write Bit
Chip Select
A2
Acknowledge Bit
Bits
A1
A0
R/W
ACK

Related parts for 24vl014