DS1904L-F5 Maxim Integrated Products, DS1904L-F5 Datasheet

no-image

DS1904L-F5

Manufacturer Part Number
DS1904L-F5
Description
RTC Ibutton
Manufacturer
Maxim Integrated Products
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS1904L-F5#
Manufacturer:
Maxim
Quantity:
245
Part Number:
DS1904L-F5+
Manufacturer:
XILINX
Quantity:
101
iButton DESCRIPTION
The DS1904 RTC iButton is a rugged real-time clock module that can be accessed with minimal
hardware. Data is transferred serially via the 1-Wire protocol, which requires only a single data lead and a
ground return. The DS1904 contains a unique 64-bit factory-lasered ROM and a real-time clock/calendar
implemented as a binary counter. The durable MicroCan package is highly resistant to environmental
www.iButton.com
SPECIAL FEATURES
§ Real-Time Clock/calendar in binary format
§ Uses the same binary time/date representation
§ Clock accuracy is better than ± 2 minutes per
§ Operating temperature range from -40°C to
§ Over 10 years of operation
COMMON iButton FEATURES
§ Unique, factory–lasered and tested 64-bit
§ Multidrop controller for MicroLAN
§ Digital identification and information by
§ Chip-based data carrier compactly stores in-
§ Data can be accessed while affixed to object
§ Economically communicates to host with a
§ Standard 16 mm diameter and 1-Wire proto-
§ Button shape is self-aligning with cup-shaped
§ Durable stainless steel case engraved with
§ Easily affixed with self-stick adhesive back-
as the DS1994 but with 1 second resolution
month at 25°C
+70°C
registration number (8-bit family code + 48-
bit serial number + 8-bit CRC tester) assures
absolute traceability because no two parts are
alike
momentary contact
formation
single digital signal at 16.3k bits per second
col ensure compatibility with iButton Device
family
probes
registration number withstands harsh envi-
ronments
ing, latched by its flange, or locked with a
ring pressed onto its rim
1 of 12
§ Presence detector acknowledges when reader
§ Meets UL#913 (4th Edit.); Intrinsically Safe
F5 MicroCanÔ
DATA
ORDERING INFORMATION
DS1904L-F5
EXAMPLES OF ACCESSORIES
DS9096P
DS9101
DS9093RA
DS9093A
DS9092
0.36
GROUND
first applies voltage
Apparatus, Approved under Entity Concept
for use in Class I, Division 1, Group A, B, C
and D Locations (application pending)
5.89
All dimensions are shown in millimeters
0.51
YYWW REGISTERED RR
40
000000FBC52B
F5 MicroCan
Self-Stick Adhesive Pad
Multi-Purpose Clip
Mounting Lock Ring
Snap-In Fob
iButton Probe
RTC iButton
24
DS1904
16.25
120402
17.35

Related parts for DS1904L-F5

DS1904L-F5 Summary of contents

Page 1

... Class I, Division 1, Group and D Locations (application pending) F5 MicroCanÔ 5.89 0.36 0.51 YYWW REGISTERED RR 40 000000FBC52B DATA GROUND All dimensions are shown in millimeters ORDERING INFORMATION DS1904L-F5 F5 MicroCan EXAMPLES OF ACCESSORIES DS9096P Self-Stick Adhesive Pad DS9101 Multi-Purpose Clip DS9093RA Mounting Lock Ring DS9093A Snap-In Fob DS9092 iButton Probe ...

Page 2

Accessories permit the DS1904 to be mounted on almost any surface including printed circuit boards and plastic key fobs. The DS1904 adds functions such as calendar, time and date stamp, stopwatch, hour meter, ...

Page 3

HIERARCHICAL STRUCTURE FOR 1-WIRE PROTOCOL Figure 2 Bus Master Command Level 1-Wire ROM Commands (see Figure DS1904 Function (see Figure 64-BIT LASERED ROM Figure 3 MSB 8-Bit CRC Code MSB LSB 1-WIRE CRC GENERATOR Figure 4 1ST 2ND 3RD STAGE ...

Page 4

TIMEKEEPING A 32.768 kHz crystal oscillator is used as the time base for the real-time clock counter. The oscillator can be turned on or off under software control. The oscillator must be on for the real time clock to function. ...

Page 5

CLOCK FUNCTION COMMAND FLOW CHART Figure 5 Master TX Control Function Command 66H Read Clock ? Y DS1904 copies RTC Counter to R/W Buffer Bus Master RX Device Control Byte Bus Master RX LS Byte (7:0) Bus Master RX next ...

Page 6

READ CLOCK [66h] The read clock command is used to read the device control byte and the contents of the real-time clock counter. After having received the most significant bit of the command code the device copies the actual contents ...

Page 7

The idle state for the 1-Wire bus is high. If for any reason a transaction needs to be suspended, the bus MUST be left in the idle state if the transaction is to resume. If this does not occur and ...

Page 8

ROM FUNCTIONS FLOW CHART Figure 7 33H N Read ROM Command ? Y DS1904 TX Family Code 1 Byte DS1904 TX Serial Number 6 Bytes DS1904 TX CRC Byte Master TX Reset Pulse DS1904 TX Presence Pulse Master TX ROM ...

Page 9

Skip ROM [CCh] This command can save time in a single drop bus system by allowing the bus master to access the clock functions without providing the 64-bit ROM code. If more than one slave is present on the bus ...

Page 10

READ/WRITE TIMING DIAGRAM Figure 9 Write-one Time Slot V PULLUP V PULLUP MIN V IH MIN V IL MAX 0V RESISTO MASTER Write-zero Time Slot V PULLUP V PULLUP MIN V IH MIN V IL MAX 0V RESISTOR MASTER Read-data ...

Page 11

PHYSICAL SPECIFICATION Size Weight Humidity Altitude Expected Service Life Safety ABSOLUTE MAXIMUM RATINGS* Voltage on 1-Wire to Ground Operating Temperature Storage Temperature * This is a stress rating only and functional operation of the device at these or any other ...

Page 12

NOTES: 1. All voltages are referenced to ground external pull-up voltage. PUP 3. Input load is to ground. 4. Read data setup time refers to the time the host must pull the 1-Wire bus low to read ...

Related keywords