ncn4-12gm35-n0-5m Pepperl+Fuchs, ncn4-12gm35-n0-5m Datasheet - Page 5

no-image

ncn4-12gm35-n0-5m

Manufacturer Part Number
ncn4-12gm35-n0-5m
Description
Inductive Sensor
Manufacturer
Pepperl+Fuchs
Datasheet
Subject to modifications without notice
Pepperl+Fuchs Group
www.pepperl-fuchs.com
ATEX 3D
Note
Instruction
Directive conformity
Standard conformity
CE symbol
Ex-identification
General
Installation, Comissioning
Maintenance
Special conditions
Device category 3D
Minimum series resistance R
Maximum operating voltage U
Maximum heating (Temperature rise)
EN 60947-5-6
Protection from mechanical danger
Electrostatic charging
Protection of the connection cable
Inductive sensor
at U
using an amplifier in accordance with
Bmax
=9 V, R
fa-info@us.pepperl-fuchs.com
V
=562 Ω
USA: +1 330 486 0001
V
Bmax
This instruction is only valid for products according to EN 50281-1-1, valid until 30-September-2008
Note the ex-marking on the sensor or on the enclosed adhesive label
Manual electrical apparatus for hazardous areas
for use in hazardous areas with non-conducting combustible dust
94/9/EG
EN 50281-1-1
Protection via housing
Use is restricted to the following stated conditions
¬ II 3D IP67 T 109 °C (228.2 °F) X
The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual.
The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to!
Laws and/or regulations and standards governing the use or intended usage goal must be observed.
No changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible.
A minimum series resistance RV is to be provided between the power supply voltage and the proximity switch in accordance
with the following list. This can also be assured by using a switch amplifier.
The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances
are not permitted.
Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum series
resistance Rv.
9 K
9 K
The sensor must not be mechanically damaged.
Electrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the
mechanical housing components can be avoided by incorporating these in the equipotential bonding.
The connection cable must be prevented from being subjected to tension and torsional loading.
0102
Germany: +49 621 776-4411
fa-info@pepperl-fuchs.com
fa-info@sg.pepperl-fuchs.com
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
NCN4-12GM35-N0-5M