tl22xi Communications & Power Industries, Inc., tl22xi Datasheet - Page 2

no-image

tl22xi

Manufacturer Part Number
tl22xi
Description
2.25 2.50 Superlinear Amplifiers
Manufacturer
Communications & Power Industries, Inc.
Datasheet
• Integral Linearizer
• Remote Control Panel
• Redundant and Power
• External Receive Band
• Integral L-Band Block
X-B an d
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifi cations may change without notice as a result of additional data or product refi nement.
Please contact CPI before using this information for system design.
MKT 189, ISSUE 5
Combined Subsystems
Reject Filter
Upconverter (BUC)
O P T I O N S &
C O M P A N I O N
P R O D U C T S :
02/08
Certificate Number: 30515
PDF
SPECIFICATIONS, TL22XI and TL25XI
Electrical
Frequency
Output Power
Linear Power
Bandwidth
Gain
RF Level Adjust
Output Power Adjustability
Gain Stability
Small Signal Gain Slope
Small Signal Gain Variation
Input/Output VSWR
Load VSWR
Residual AM, max.
Phase Noise
AM/PM Conversion
Harmonic Output
Noise and Spurious
Intermodulation
IESS-308/309
AC fundamentals related
Sum of spurs
with two equal carriers,
total output power
level at 56 dBm
TWT - TL22XI
TWT - TL25XI
Flange - TL25XI
TL22XI
TL25XI
phase noise continuous
Flange - TL22XI
1
1
7.9 - 8.4 GHz
2250 W min. (63.54 dBm)
2500 W min. (63.98 dBm)
1000 W max. operating (60.00 dBm)
1110 W max. operating (60.45 dBm)
1000 W with linearizer option
1110 W with linearizer option
500 MHz
75 dB min. at rated power output
78 dB min. at small signal
0 to 30 dB continuous
±0.1 dB
±0.25 dB/24 hr max.
(at constant drive and temp.)
0.02 dB/MHz max.
0.5 dB pk-pk max. over any 40 MHz;
3.0 dB pk-pk max. across the
4.0 dB pk-pk w/linearizer;
5.0 dB pk-pk w/ BUC;
6.0 dB pk-pk w/linearizer and BUC
1.25:1 max.
2.0:1 max. for full spec compliance;
any value without damage
-50 dBc below 10 kHz,
-20 (1.5 +log F kHz) dBc,
-85 dBc above 500 kHz
10 dB below mask at -10 dB backof
-50 dBc
-47 dBc
6°/dB max. With optional linearizer,
can be tuned to 2°/dB max.
-80 dBc
-130 dBW/4 kHz from 3.4 to 4.2 GHz
-65 dBW/4 kHz from 4.2 to 12.0 GHz
-110 dBW/4 kHz from 12.0 to 40.0 GHz
-23.5 dBc max, 7.9 - 8.4 GHz
(-25 dBc max. at 4 dB backoff
10 kHz to 500 kHz (F in kHz)
500 MHz band;
with linearizer);
3
Electrical (continued)
Group Delay
Primary Power
Power Factor
Power Consumption
Environmental
Ambient Temperature
Relative Humidity
Altitude
Shock and Vibration
Mechanical
Cooling(TWT)
RF Input Connection
RF Output Connection
RF Power Monitors
Dimensions (W x H x D)
Weight
1 Prime power AC line unbalance not to exceed 3%. Excess imbalance may cause
2 AC current harmonic content: less than 20%, primarily fifth and seventh harmonics. Harmonics
3 Up to 1250 watts linear power available through optimization of linearizer settings.
an increase in residual RF noise (AM, FM and PM). Phase noise increase is typically 2.5 dB / %
imbalance.
must be considered when choosing UPS sources.
(in any 40 MHz band)
2
0.02 ns/MHz linear
0.002 ns/MHz
0.5 ns pk-pk ripple max.
All ratings are ±10%, 47-63 Hz, 5-wire,
3-phase with neutral and ground
0.95 min.
5.5 kW max.;
4.9 kW typ. @ 1000 W linear RF output
4.2 kW typ. @ 800 W;
3.9 kW typ. @ 600 W;
3.6 kW typ. @ 400 W;
3.3 kW typ. @ 200 W;
2.8 kW typ. @ 100 W
(Power consumption 10% less for
2.25 kW HPA, typ.)
-10° to +50°C operating
-40° to +71°C non-operating
95% non-condensing
Up to 10,000 ft (3000 m) with standard
adiabatic derating of 2°/1000 ft.;
50,000 feet non-operating
Designed for normal transportation
environment per Section 514.4
MIL-STD-810E. Designed to withstand
20g at 11 ms (1/2 sine pulse) in
non-operating condition
Forced air with integral blower
and power supply fan. Maximum
external pressure loss allowable:
0.25 inch water gauge.
Type N female
CPR 112 F waveguide fl ange,
grooved, threaded UNF 2B 10-32
Type N female
19 x 15.75 x 24 in.
(483 x 400 x 610 mm)
155 lbs. (70.5 kg) max.
power;
208 VAC (with or w/o neutral)
380 to 415 VAC
2
parabolic

Related parts for tl22xi