a5364 Allegro MicroSystems, Inc., a5364 Datasheet

no-image

a5364

Manufacturer Part Number
a5364
Description
Ionization Smoke Detector With Interconnect
Manufacturer
Allegro MicroSystems, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
a5364CA
Manufacturer:
ALLEGRO/雅丽高
Quantity:
20 000
Features and Benefits
▪ Low average standby current for long battery life
▪ Interconnect up to 125 detectors
▪ Piezoelectric horn driver
▪ Guard outputs for detector input
▪ Pulse testing for low battery
▪ Power-on reset (POR)
▪ Internal reverse battery protection
▪ Built-in hysteresis reduces false triggering
▪ Temporal horn pattern, per UL217, NFPA72, and ISO8201
▪ UL Recognized for UL217 applications, per file # S2113
Package: 16-pin DIP (suffix A)
Not to scale
26110.7D
9 V
To / from
other units
1 μF
8.2 MΩ
200 Ω
B
330 Ω
1
2
3
4
5
6
7
8
NC
I/O
LOW-V SET
NC
LED
VDD
TIMING RES
FEEDBACK
A5364
200 kΩ
SENSITIVITY SET
Typical Application
DETECT IN
OSC CAP
GUARD1
GUARD2
HORN2
HORN1
VSS
16
15
14
13
12
11
10
9
Description
The A5364 is a low-current, CMOS circuit providing all of
the required features for an ionization-type smoke detector.
A networking capability allows as many as 125 units to be
interconnected so that if any unit senses smoke all units will
sound their alarm. In addition, special features are incorporated
to facilitate alignment and test of the finished smoke detector.
The device is Recognized by Underwriters Laboratories for use
in smoke alarms that comply with Standard UL217.
The internal oscillator and timing circuitry keep standby power
to a minimum by powering down the device for 1.66 seconds
and sensing for smoke for only 10 ms. Every 24 on-off cycles,
a check is made for a low battery condition. By substituting
other types of sensors or a switch for the ionization detector,
this very-low–power device can be used in numerous other
battery-operated safety/security applications.
The A5364 is supplied in a low-cost 16-pin dual in-line plastic
package (DIP). It is rated for continuous operation over the
temperature range of 0°C to 50°C. The Pb (lead) free version
(suffix –T) has 100% matte tin leadframe plating.
0.1 μF
Ionization Smoke Detector
1.5 MΩ
220 kΩ
A
C
200 k Ω
C
Push
to Test
A
B
0.001 μF
C
with Interconnect
Use an external resistor to adjust
sensitivity for a particular smoke chamber.
C
A resistor to VSS or VDD may
be added to this pin to modify
low battery voltage threshold.
Value of component will vary, based on
the piezoelectric horn used.
A5364

Related parts for a5364

a5364 Summary of contents

Page 1

... The A5364 is supplied in a low-cost 16-pin dual in-line plastic package (DIP rated for continuous operation over the temperature range of 0°C to 50°C. The Pb (lead) free version (suffix – ...

Page 2

... A5364 Selection Guide Part Number Pb-Free A5364CA-T Yes A5364CA – Absolute Maximum Ratings* Characteristic Supply Voltage Range Input Voltage Range Reverse Battery Condition Duration Input Current Operating Ambient Temperature Junction Temperature Storage Temperature Range * CAUTION: CMOS devices have input static protection but are susceptible to damage when exposed to extremely high static electrical charges. ...

Page 3

... A5364 +Supply 9V VDD LBSamp Low Battery Sample LOW-V SET SENSITIVITY SET SSamp Smoke Sample -Supply VSS Functional Block Diagram I Band Gap Low Battery 600 kΩ Comparator _ Logic + 500 kΩ Smoke Comparator LBSamp 1.1 MΩ SSamp Oscillator and Timing + _ GUARD1 DETECT IN GUARD2 ...

Page 4

... A5364 ELECTRICAL CHARACTERISTICS R = 8.2 MΩ (unless otherwise noted) TIMINGRES Characteristic Symbol Supply Voltage Range V DD Supply Current I DD Detector Input Current I DETECTIN V OS(GUARD1) Input Offset Voltage V OS(GUARD2 Hysteresis V HYS V CM(guard) Common Mode Range AG1 Active Guard Impedance Z AG2 t osc ...

Page 5

... Detector Circuitry When the voltage on the DETECT IN pin is less than the volt- age on the SENSITIVITY SET pin, the A5364 evaluates this as a smoke condition. During a smoke condition, the resistor divider network that sets the sensitivity (also referred to as the smoke trip ...

Page 6

... A5364 of the ionization chamber by connecting a resistor between the SENSITIVITY SET pin and either the VDD or VSS pins. With no external connections on the SENSITIVITY SET pin, while the A5364 is checking for smoke SENSITIVITYSET To increase sensitivity, a resistor can be connected between SENSITIVITY SET and VDD, with the value: = 1.1E6 × ...

Page 7

... A5364 Standby Mode OSC CAP Pin Internal Clock Smoke Sample Low Battery Test LED Pin Low Battery Condition VDD Pin Low Battery Test LED Pin LED off (High-Z) Horn Enable Ionization Smoke Detector Timing Diagrams (Not to scale) Test event t t osc ...

Page 8

... A5364 Local Smoke Detection/Test Alarm Condition Test event Smoke Sample Smoke Chamber LED Pin LED on Horn Enable I/O Pin Remote Alarm Condition LED Pin Horn Enable I/O Pin t osc(alarm) OSC CAP Pin Internal Clock Smoke Sample LED Pin 24 clock cycles V < V (smoke) DETECTIN ...

Page 9

... A5364 A .005 [1.27] Allegro MicroSystems offers an industry-leading range of ionization and photoelectric smoke detector ICs. For a current listing, please visit our website at: Copyright ©2001, 2007, Allegro MicroSystems, Inc. The products described here are manufactured under one or more U.S. patents or U.S. patents pending. Allegro MicroSystems, Inc. reserves the right to make, from time to time, such de par tures from the detail spec tions as may be required to per- mit improvements in the per for mance, reliability, or manufacturability of its products ...

Related keywords