mlx90807 Melexis Company, mlx90807 Datasheet

no-image

mlx90807

Manufacturer Part Number
mlx90807
Description
Relative Integrated Pressure Sensor
Manufacturer
Melexis Company
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mlx90807LUF-AAA-000-WB
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90807LUF-CAA-001-WB
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90807LUS-CAA-001-SP
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90807LUS-CAA-001-WP
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Features and Benefits
Application Examples
Ordering Information
Part No.
MLX90807
3901090807
Rev 003
1 Functional Diagram
Relative Integrated Pressure sensor
Less than 1% error range overall
Programmable through the connector (3 pins)
Trimmable offset and sensitivity
Ratiometric output
Rail-to-Rail output
Output proportional to the applied pressure
Diagnostics of broken supply wires and broken sensor
Output protected against short-circuits at both battery terminals
On-chip Signal Conditioning (single die solution)
Different pressure ranges available
Automotive applications (vapour pressure, filter quality monitoring, …)
Industrial applications
Medical applications (respirator, …)
Temperature Suffix
L (-40° C to 150°C)
Package Code
UF (die on foil)
Page 1 of 8
Relative Integrated Pressure Sensor
The MLX90807 is an integrated relative
pressure sensor realised in CMOS
technology. It consists of an analog signal
chain that interacts with the digital core and
on-chip temperature sensor in order to
provide uniform overall sensing
characteristics after calibration and to cancel
the temperature related parameter drifts.
The output is proportional to the applied
pressure with an adjustable slope and offset.
The chip is ratiometric and goes rail-to-rail
with a 1mA source and sink capability.
2
Option
- 0
General Description
Description
100 mBar Full Scale
MLX90807
Data Sheet
Feb 08

Related parts for mlx90807

mlx90807 Summary of contents

Page 1

... Package Code Option UF (die on foil General Description The MLX90807 is an integrated relative pressure sensor realised in CMOS technology. It consists of an analog signal chain that interacts with the digital core and on-chip temperature sensor in order to provide uniform overall sensing characteristics after calibration and to cancel the temperature related parameter drifts ...

Page 2

... General Electrical Specifications....................................................................................... 3 5 Diagnostic features ........................................................................................................... 4 6 Detailed General Description ............................................................................................ 4 7 Unique Features ............................................................................................................... 5 8 Application Information ..................................................................................................... 5 9 Programming and Calibration ........................................................................................... 6 9.1 Programming of the Temporary Memory of 90807 ..................................................... 6 9.2 Zapping of the 90807 .................................................................................................. 7 10 Disclaimer ....................................................................................................................... 8 3901090807 Rev 003 MLX90807 Relative Integrated Pressure Sensor Page Data Sheet Feb 08 ...

Page 3

... Symbol Test Conditions Table 2: Electrical specifications 3901090807 Rev 003 Relative Integrated Pressure Sensor Symb Min Value Max Value 140 (unless otherwise specified Page MLX90807 Units ° ° ° Min Typ Max Units o Data Sheet Feb 08 ...

Page 4

... No additional pins are necessary for calibration. The output circuit is protected against short circuit to GND, Vbat (16V) and V 3901090807 Rev 003 Relative Integrated Pressure Sensor 140 (unless otherwise specified) DD Test Conditions Page MLX90807 Min Typ Max Units . dd Data Sheet Feb 08 ...

Page 5

... Very few off-chip components are needed (only 2 decoupling capacitors, not higher than 100 nF). Only 3 pins are used (Vdd, Vss, Out), see pad layout drawing in paragraph 9. Calibration and Programming is made through the OUT pin. 3901090807 Rev 003 MLX90807 Relative Integrated Pressure Sensor Page 47nF Data Sheet ...

Page 6

... You can input the data through the OUT pin. The data is Pulse Width modulated. At the end of the programming, we keep OUT high until VCC has reached his normal level (VCC_N). Thereafter we disconnect OUT not necessary power-down before the next settings are programmed. Timings 3901090807 Rev 003 MLX90807 Relative Integrated Pressure Sensor Page Data Sheet Feb 08 ...

Page 7

... The supply current should be measured at the normal supply voltage. A low current (ICC_R0) indicates that the zap cell is not programmed. A high current (ICC_R1) indicates that the zap cell is programmed. 3901090807 Rev 003 MLX90807 Relative Integrated Pressure Sensor Page Data Sheet Feb 08 ...

Page 8

... For the latest version of this document our website at Or for additional information contact Melexis Direct: Europe, Africa, Asia: Phone: +32 1367 0495 E-mail: sales_europe@melexis.com 3901090807 Rev 003 Relative Integrated Pressure Sensor www.melexis.com America: Phone: +1 603 223 2362 E-mail: sales_usa@melexis.com ISO/TS 16949 and ISO14001 Certified Page MLX90807 Data Sheet Feb 08 ...