hi5960 Intersil Corporation, hi5960 Datasheet - Page 3

no-image

hi5960

Manufacturer Part Number
hi5960
Description
14-bit, 130msps, Commlink? High Speed D/a Converter
Manufacturer
Intersil Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
hi5960IA
Manufacturer:
NS
Quantity:
4
Part Number:
hi5960IA
Manufacturer:
HARRIS
Quantity:
27
Part Number:
hi5960IA
Manufacturer:
MX
Quantity:
6 222
Part Number:
hi5960IAZ
Manufacturer:
INTERSIL
Quantity:
20 000
Part Number:
hi5960IB
Manufacturer:
TCXO
Quantity:
286
Part Number:
hi5960IBZ
Manufacturer:
TI
Quantity:
222
Part Number:
hi5960IBZ
Manufacturer:
INTERSIL
Quantity:
20 000
Pin Descriptions
PIN NO.
20, 25
1-14
15
16
17
18
19
21
22
23
24
26
27
28
D13 (MSB) Through
PIN NAME
D0 (LSB)
COMP1
COMP2
REFLO
SLEEP
FSADJ
REFIO
IOUTB
IOUTA
DCOM
ACOM
AV
DV
CLK
DD
DD
3
Digital Data Bit 13, (Most Significant Bit) through Digital Data Bit 0, (Least Significant Bit).
Control Pin for Power-Down mode. Sleep Mode is active high; Connect to ground for Normal Mode. Sleep
pin has internal 20µA active pulldown current.
Connect to analog ground to enable internal 1.2V reference or connect to AV
reference.
Reference voltage input if internal reference is disabled. Reference voltage output if internal reference is
enabled. Use 0.1µF cap to ground when internal reference is enabled.
Full Scale Current Adjust. Use a resistor to ground to adjust full scale output current. Full Scale Output
Current = 32 x V
For use in reducing bandwidth/noise. Recommended: connect 0.1µF to AV
The complimentary current output of the device. Full scale output current is achieved when all input bits
are set to binary 0.
Current output of the device. Full scale output current is achieved when all input bits are set to binary 1.
Connect 0.1µF capacitor to ACOM.
Analog Supply (+3V to +5V).
Connect to Analog Ground.
Connect to Digital Ground.
Digital Supply (+3V to +5V).
Clock Input. Input data to the DAC passes through the “master” latches when the clock is low and is
latched into the “master” latches when the clock is high. Data presented to the “slave” latch passes
through when the clock is logic high and is latched into the “slave” latches when the clock is logic low.
Adequate setup time must be allowed for the MSBs to pass through the thermometer decoder before the
clock goes high. This master-slave arrangement comprises an edge-triggered flip-flop, with the DAC
being updated on the rising clock edge. It is recommended that the clock edge be skewed such that setup
time is larger than the hold time.
FSADJ
/R
SET
HI5960
.
DESCRIPTION
DD
DD
.
to disable internal