x9429wv14iz-2.7t2 Intersil Corporation, x9429wv14iz-2.7t2 Datasheet

no-image

x9429wv14iz-2.7t2

Manufacturer Part Number
x9429wv14iz-2.7t2
Description
Single Digitally Controlled Potentiometer Xdcp?
Manufacturer
Intersil Corporation
Datasheet
Single Digitally Controlled Potentiometer
(XDCP™)
FEATURES
• Single Voltage Potentiometer
• 64 Resistor Taps
• 2-wire Serial Interface for Write, Read, and
• Wiper Resistance, 150Ω Typical at 5V
• Non-Volatile Storage of Multiple Wiper Positions
• Power-on Recall. Loads Saved Wiper Position
• Standby Current < 5µA Max
• V
• 2.5kΩ, 10kΩ Total Pot Resistance
• Endurance: 100, 000 Data Changes per Bit per
• 100 yr. Data Retention
• 14 Ld TSSOP, 16 Ld SOIC
• Low Power CMOS
• Pb-Free Plus Anneal Available (RoHS Compliant)
BLOCK DIAGRAM
Transfer Operations of the Potentiometer
on Power-up.
Register
CC
2-wire
bus
interface
: 2.7V to 5.5V Operation
address
status
data
®
1
Interface &
Control
V
Bus
V
SS
CC
Data Sheet
transfer
inc / dec
write
control
read
1-888-INTERSIL or 1-888-468-3774
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
XDCP is a trademark of Intersil Americas Inc. Copyright Intersil Americas Inc. 2005. All Rights Reserved
Power-on Recall
Register (WCR)
Wiper Counter
Data Registers
4 Bytes
DESCRIPTION
The X9429 integrates a single digitally controlled
potentiometer
integrated circuit.
The digital controlled potentiometer is implemented
using 63 resistive elements in a series array. Between
each element are tap points connected to the wiper
terminal through switches. The position of the wiper on
the array is controlled by the user through the 2-wire
bus interface. The potentiometer has associated with it
a volatile Wiper Counter Register (WCR) and a four
non-volatile Data Registers that can be directly written
to and read by the user. The contents of the WCR
controls the position of the wiper on the resistor array
though the switches. Powerup recalls the contents of
the default data register (DR0) to the WCR.
The XDCP can be used as a three-terminal
potentiometer or as a two terminal variable resistor in
a wide variety of applications including control,
parameter adjustments, and signal processing.
October 19, 2005
All other trademarks mentioned are the property of their respective owners.
V
Low Noise/Low Power/2-Wire Bus
L
|
/R
Intersil (and design) is a registered trademark of Intersil Americas Inc.
L
wiper
V
V
H
(XDCP)
W
/R
/R
H
POT
W
10kΩ
64-taps
on
a
monolithic
X9429
FN8248.2
CMOS

Related parts for x9429wv14iz-2.7t2

x9429wv14iz-2.7t2 Summary of contents

Page 1

Data Sheet Single Digitally Controlled Potentiometer (XDCP™) FEATURES • Single Voltage Potentiometer • 64 Resistor Taps • 2-wire Serial Interface for Write, Read, and Transfer Operations of the Potentiometer • Wiper Resistance, 150Ω Typical at 5V • Non-Volatile Storage ...

Page 2

... X9429WS16-2.7* X9429WS F X9429WS16Z-2.7* (Note) X9429WS Z F X9429WS16I-2.7* X9429WS G X9429WS16IZ-2.7* (Note) X9429WS Z G X9429WV14-2.7* X9429WV F X9429WV14Z-2.7* (Note) X9429WV Z F X9429WV14I-2.7* X9429WV G X9429WV14IZ-2.7* (Note) X9429WV Z G X9429YS16-2.7* X9429YS F X9429YS16Z-2.7* (Note) X9429YS Z F X9429YS16I-2.7* X9429YS G X9429YS16IZ-2.7* (Note) X9429YS Z G X9429YV14-2.7* X9429YV F X9429YV14Z-2.7* (Note) X9429YV Z F X9429YV14I-2 ...

Page 3

DETAILED FUNCTIONAL DIAGRAM V CC SCL INTERF A CE SDA AND CONTROL A3 CIRCUITR CIRCUIT LEVEL APPLICATIONS • Vary the gain of a voltage amplifier • Provide programmable dc reference voltages for comparators and detectors ...

Page 4

PIN CONFIGURATION SCL 5 SDA 6 VSS 7 PIN ASSIGNMENTS TSSOP pin SOIC pin ...

Page 5

The wiper outputs are equivalent to the wiper output of a mechanical potentiometer. Hardware Write Protect Input WP The WP pin when low prevents nonvolatile writes to the Data Registers. PRINCIPLES OF OPERATION The X9429 is ...

Page 6

Acknowledge Polling The disabling of the inputs, during the internal nonvolatile write operation, can be used to take advantage of the typical 5ms EEPROM write cycle time. Once the stop condition is issued to indicate the end of the nonvolatile ...

Page 7

Figure 3. Two-Byte Instruction Sequence SCL SDA Read Wiper Counter Register (read the current wiper position of the selected pot), write Wiper Counter Register (change current wiper position of the selected pot), ...

Page 8

Figure 4. Three-Byte Instruction Sequence SCL SDA Figure 5. Increment/Decrement Instruction Sequence SCL SDA Figure 6. ...

Page 9

Figure 7. Acknowledge Response from Receiver SCL from Master Data Output from Transmitter Data Output from Receiver START Figure 8. Detailed Potentiometer Block Diagram Serial Data Path From Interface Circuitry Register 0 Register 2 If WCR = 00[H] then V ...

Page 10

DETAILED OPERATION The potentiometer has a Wiper Counter Register and four Data Registers. A detailed discussion of the register organization and array operation follows. Wiper Counter Register The X9429 contains a Wiper Counter Register. The Wiper Counter Register can be ...

Page 11

Instruction Format Notes: (1) “MACK”/”SACK”: stands for the acknowledge sent by the master/slave. (2) “A3 ~ A0”: stands for the device addresses sent by the master. (3) “X”: indicates that “0” for testing purpose but physically it ...

Page 12

XFR Wiper Counter Register (WCR) to Data Register (DR) S device type device instruction S T identifier addresses Increment/Decrement ...

Page 13

ABSOLUTE MAXIMUM RATINGS Temperature under bias : ........................-65°C to +135°C Storage temperature: .............................-65°C to +150°C Voltage on SCL, SDA any address input with respect ...................................-1V to +7V SS ∆ .............................................................5V ...

Page 14

D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.) Symbol Parameter I V supply current CC1 CC (nonvolatile write supply current CC2 CC (move wiper, write, read current (standby Input leakage ...

Page 15

A.C. TEST CONDITIONS I nput pulse levels V Input rise and fall times 10ns Input and output timing level V EQUIVALENT A.C. LOAD CIRCUIT 5V 1533Ω SDA Output 100pF AC TIMING (Over recommended operating conditions) Symbol f Clock frequency SCL ...

Page 16

HIGH-VOLTAGE WRITE CYCLE TIMING Symbol t High-voltage write cycle time (store instructions) WR XDCP TIMING Symbol t Wiper response time after the third (last) power supply is stable WRPO t Wiper response time after instruction issued (all load instructions) WRL ...

Page 17

XDCP Timing (for All Load Instructions) SCL SDA XDCP Timing (for Increment/Decrement Instruction) SCL Wiper Register Address SDA Write Protect and Device Address Pins Timing SCL SDA WP A0 ...

Page 18

APPLICATIONS INFORMATION Basic Configurations of Electronic Potentiometers V R Three terminal Potentiometer; Variable voltage divider Application Circuits Noninverting Amplifier – (1 Offset Voltage Adjustment R ...

Page 19

Application Circuits (continued) Attenuator – All -1/2 ≤ G ≤ +1/2 Inverting Amplifier – ...

Page 20

PACKAGING INFORMATION 0° - 8° See Detail “A” NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 20 X9429 14-Lead Plastic, TSSOP, Package Type V .025 (.65) BSC .169 (4.3) .177 (4.5) .193 (4.9) .200 (5.1) .0075 (.19) .002 (.05) ...

Page 21

... Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use ...

Related keywords