idt49c460cjb Integrated Device Technology, idt49c460cjb Datasheet - Page 18

no-image

idt49c460cjb

Manufacturer Part Number
idt49c460cjb
Description
32-bit Cmos Error Detection And Correction Unit
Manufacturer
Integrated Device Technology
Datasheet
IDT49C460/A/B/C/D/E
32-BIT CMOS ERROR DETECTION AND CORRECTION UNIT
IDT49C460E AC ELECTRICAL CHARACTERISTICS
(Guaranteed Commercial Range Performance) Temperature range: 0 C to +70 C, V
The inputs switch between 0V to 3V with signal measured at the 1.5V level.
PROPAGATION DELAYS
SET-UP AND HOLD TIMES RELATIVE TO LATCH ENABLES
OUTPUT ENABLE/DISABLE TIMES
NOTES:
1. CI = 50pF.
2. These parameters are combinational propagation delay calculations, and are not tested in production.
3. Data In or Correct Data Out measurement requires timing as shown in the Switching Waveforms.
4. Set-up and Hold times relative to Latch Enables (Latching Data).
5. Output tests specified with CI = 5pF and measured to 0.5V change of output level. Testing is performed at CI = 50pF and correlated to CI = 5pF.
6. Not production tested, guaranteed by characterization.
NOTE: (15) above applies to correction path.
MINIMUM PULSE WIDTHS
Internal
Control
Mode
DATA
CB
DATA
CB
CB
CORRECT
DIAG MODE
CODE ID
LE
DATA
OE Byte
OE
LE
IN (4, 6)
0–7 (4)
0–7
0–7
IN
SC
0–31 (4)
0–31 (4, 6)
0–31 (4, 6)
, LE
(CODE ID 00, 11)
(CODE ID 10)
DATA
CB
CB
LE
CORRECT
Not Internal Control Mode
DIAG MODE
Not Internal Control Mode
CODE ID
LE
From latched to Transparent
LE
From latched to Transparent
LE
latched to Transparent
DATA
Via Diagnostic Latch
1,0 (4, 6)
0–3
OUT
(4, 6)
From Input
OUT
IN
DIAG
DIAG
0–7
0–7
(4, 6)
/
GENERATE
0–31 (3)
0–31
/
(CODE ID
(CODE ID
GENERATE
(Internal Control Mode) From
1,0
(Internal Control Mode)
(4, 6)
From Input
From Input
(4, 6)
1,0
1,0
, LE
= 00, 11)
= 10)
DIAG
(1)
ud ud
Enable
(Positive–going pulse)
d d
d d
(5)
u u
d d
u u
u u
u u
Disable
u u d d
u u d d
u u
u u
d d
d d
d d
d d
d d
d d
d d
SC
13
11
11
11
13
11
16
11
9
9
0–7
(6)
(6)
(6)
11.6
(Latching Data)
LE
LE
LE
LE
LE
LE
LE
To Input
OUT
OUT
OUT
OUT
OUT
OUT
OUT
To Output
DATA
LE
SC
/
/
/
/
/
/
/
LE
LE
GENERATE
GENERATE
GENERATE
GENERATE
GENERATE
GENERATE
GENERATE
DATA
DIAG
0–7
IN
IN
0–31
14
17
12
10
11
18
17
19
17
16
9
MILITARY AND COMMERCIAL TEMPERATURE RANGES
(2)
(2)
0–31
To Output
Min.
Set-up Time
d d
u u
0
0
Enable
ERROR
ERROR
CC
Min.
5
10
12
13
11
11
11
13
14
(15)
7
8
9
3
2
6
6
8
3
= 5.0V
Max.
7
7
7
7
MULT ERROR
MULT ERROR
Min.
Min.
5%
d d
u u
0
0
5
Disable
Hold Time
Min.
14
16
11
15
13
13
11
9
3
3
0
0
0
0
0
0
0
3
Max.
6
6
8
8
2584 tbl 70
2584 tbl 72
2584 tbl 71
2584 tbl 73
Unit
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Unit
ns
18
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns

Related parts for idt49c460cjb