ncb10-30gm40-z1-3g-3d Pepperl+Fuchs, ncb10-30gm40-z1-3g-3d Datasheet

no-image

ncb10-30gm40-z1-3g-3d

Manufacturer Part Number
ncb10-30gm40-z1-3g-3d
Description
Inductive Sensor
Manufacturer
Pepperl+Fuchs
Datasheet
Subject to modifications without notice
Pepperl+Fuchs Group
www.pepperl-fuchs.com
Model Number
NCB10-30GM40-Z1-3G-3D
Features
Connection
Accessories
BF 30
Mounting flange, 30 mm
Comfort series
10 mm embeddable
ATEX-approval for zone 2 and zone 22
Inductive sensor
BN
BU
fa-info@us.pepperl-fuchs.com
L+
L-
USA: +1 330 486 0001
Germany: +49 621 776-4411
fa-info@pepperl-fuchs.com
Dimensions
Technical Data
General specifications
Nominal ratings
Ambient conditions
Mechanical specifications
General information
Compliance with standards and directives
Approvals and certificates
Switching element function
Rated operating distance
Installation
Output polarity
Assured operating distance
Reduction factor r
Reduction factor r
Reduction factor r
Operating voltage
Switching frequency
Hysteresis
Reverse polarity protected
Short-circuit protection
Voltage drop
Operating current
Lowest operating current
Off-state current
Indication of the switching state
Ambient temperature
Storage temperature
Connection type
Cable version
Core cross-section
Housing material
Sensing face
Protection degree
Use in the hazardous area
Standard conformity
UL approval
CSA approval
CCC approval
Category
Standards
Al
Cu
V2A
fa-info@sg.pepperl-fuchs.com
Singapore: +65 6779 9091
Copyright Pepperl+Fuchs
s
s
U
f
H
U
I
I
I
L
m
r
n
a
B
d
36
DC
10 mm
embeddable
DC
0 ... 8.1 mm
0.32
0.28
0.7
5 ... 60 V
0 ... 150 Hz
1 ... 10 typ. 5 %
tolerant
pulsing
≤ 5 V
2 ... 100 mA
2 mA
0 ... 0.5 mA typ.
all direction LED, yellow
-25 ... 70 °C (-13 ... 158 °F)
-40 ... 85 °C (-40 ... 185 °F)
cable PVC , 2 m
PA
0.34 mm
Stainless steel
PBT
IP67
see instruction manuals
3G; 3D
EN 60947-5-2:2007
IEC 60947-5-2:2007
cULus Listed, General Purpose
cCSAus Listed, General Purpose
Products with a maximum operating voltage of ≤36 V do not bear a
CCC marking because they do not require approval.
M30x1,5
2
NC
LED
NCB10-30GM40-Z1-3G-3D
1

Related parts for ncb10-30gm40-z1-3g-3d

ncb10-30gm40-z1-3g-3d Summary of contents

Page 1

... Listed, General Purpose CSA approval cCSAus Listed, General Purpose Products with a maximum operating voltage of ≤ not bear a CCC approval CCC marking because they do not require approval. Copyright Pepperl+Fuchs Germany: +49 621 776-4411 Singapore: +65 6779 9091 fa-info@pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com NCB10-30GM40-Z1-3G-3D LED ...

Page 2

... The connection cable must be prevented from being subjected to tension and torsional loading. Subject to modifications without notice 2 Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com NCB10-30GM40-Z1-3G-3D and the max. operating voltage U L Bmax. Copyright Pepperl+Fuchs Germany: +49 621 776-4411 Singapore: +65 6779 9091 fa-info@pepperl-fuchs ...

Page 3

... The connection cable must be prevented from being subjected to tension and torsional loading. Protection of the connection cable Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com and the max. operating voltage U L Copyright Pepperl+Fuchs Germany: +49 621 776-4411 Singapore: +65 6779 9091 fa-info@pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com NCB10-30GM40-Z1-3G-3D Bmax. 3 ...

Related keywords