Description
T92-type Gbits/s 1300 Uncooled Laser Transmitter
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
T923FFAA
Manufacturer:
Triquint
Quantity:
1 400
Agere Systems Inc.
Advance Data Sheet
March 2001
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Characteristics
(Minimum and maximum values specified over operating case temperature range at 50% duty cycle data signal.
Typical values are measured at room temperature unless otherwise noted.)
Table 2. Electrical Characteristics
1. With V
2. Inputs are ac-coupled into an equivalent input impedance of 50 .
3. Single-ended or differential operation may be used. If the inputs are driven single-ended, the unused inputs (
4. Clocked operation is normally enabled and only requires an external voltage to disable. For nonclocked operation, pin 5 must be tied to V
5. With clocked operation, the optical output changes state with the rising edge of the input clock signal. The skew is measured with the rising
6. The transmitter is normally enabled and only requires an external voltage to disable.
7. This alarm will go active when the bias current to the laser has increased 50% or more from its beginning-of-life (BOL) value.
8. This voltage is measured from Pin 3 to V
9. This voltage is measured from Pin 2 to V
dc Power Supply Voltage
dc Power Supply Current Drain
Input Data/Clock Voltage:
Clocked/Nonclocked Select Voltage:
Clock/Data Input Impedance
Clock/Data RF Return Loss (50 kHz to 10 Ghz)
Clock/Data Input Skew
Transmitter Disable Voltage
Transmitter Enable Voltage
Degrade Mode Alarm Voltage–Normal
Degrade Mode Alarm Voltage–Alarmed
Laser Bias Voltage
Back-facet Monitor Voltage (50% duty cycle)
Supply Voltage
Operating Case Temperature Range
Storage Case Temperature Range
Lead Soldering Temperature/Time
Relative Humidity (noncondensing)
Minimum Fiber-Bend Radius
minated to ground.
edge of the clock centered in the middle of the data eye.
Clocked Operation
Nonclocked Operation
EE
connected to –5.2 V, V
Parameter
8
Parameter
5
1
2, 3
CC
6
Single-ended Input
must be at 0 V; With V
EE
EE
.
4
and is converted to laser bias current with the ratio of 20 mV/mA.
7
9
CC
connected to +5.0V, V
V
V
V
Symbol
V
dc
ALARMED
SEL_CLK
NORMAL
SEL CLK
S11
V
V
V
V
V
R
V
SKEW
Symbol
DIS
EN
EE
I
BF
IN
IN
B
V
T
RH
T
stg
CC
C
–5.5/+4.75
V
V
V
CC
CC
CC
Min
V
V
V
500
–25
460
EE
0
EE
EE
EE
– 2.0
– 2.0
– 2.0
must be at 0 V.
1.00 (25.4)
Uncooled DFB Laser Transmitter
Min
–40
0
T92-Type 10 Gbits/s 1300 nm
–5.2/+5.0
Typ
250
700
500
500
50
0
Clock
250/10
Max
5.5
–4.9/+5.25
70
85
85
V
V
V
and
EE
EE
EE
1000
2400
Max
V
400
V
–10
V
540
25
Data
CC
CC
CC
+ 0.8
+ 0.8
+ 0.8
) must be 50
in. (mm)
Unit
°C/s
mVp-p
°C
°C
%
V
Unit
mA
mV
mV
dB
ps
V
V
V
V
V
V
V
ter-
CC
3
.

Related parts for t923ffaa