sc2128a-c30s Silan, sc2128a-c30s Datasheet - Page 8

no-image

sc2128a-c30s

Manufacturer Part Number
sc2128a-c30s
Description
Fan Remote Control Decoder Used Together With Sc2268
Manufacturer
Silan
Datasheet
11. SLEEP WIND MODE
12. RHYTHM SLEEP WIND MODE
13. MEMORY MODE
HANGZHOU SILAN MICROELECTRONICS CO.,LTD
http:
wind level. If no off-timer is set, SC2128A keeps in low wind level. Otherwise, it restores off state when off-timer
times out. To enter sleep wind mode, turn on the fan by SPEED key first. Adjust to desired LO, MI, ST wind
speed. Press MODE key twice to bring SC2128A to LOW, MIDDLE or STRONG sleep wind mode as the LO,
MI, ST wind speed set before entering sleep wind mode. Press MODE key in sleep wind mode forces
SC2128A to leave sleep wind mode and enter rhythm sleep wind mode.
SC2128A outputs LOW, MIDDLE or STRONG rhythm wind pattern and automatically steps down one level
every 30 minutes until it reaches low rhythm wind level. If no off-timer is set, SC2128A keeps in low rhythm
wind output. Otherwise it restores off state when the off-timer times out.
functions as a special MEMS(memory start) key. If this key is pressed when SC2128A is in off state, SC2128A
is activated into the operation mode stored in the operation memory. After power on, the operation memory is
initialized as follows: middle speed, ordinary wind, none off-timer setting, SO1 and SO2 swing head outputs
both off, LIT output off.
In sleep wind mode, the wind speed steps down automatically one level every 30 minutes, until it reaches low
Pressing MODE key in sleep wind mode brings SC2128A into rhythm sleep wind. In rhythm sleep wind mode,
Operation memory memorizes the following:
SC2128A features on-chip operation memory, in which operation state may be stored. OFF/MEMS key also
www.silan.com.cn
Strong rhythm wind
Middle rhythm wind
Strong rhythm wind
Middle rhythm wind
Strong rhythm wind
Middle rhythm wind
Low rhythm wind
Low rhythm wind
Low rhythm wind
LO
LO
LO
ST
ST
ST
MI
MI
MI
t=0
t=0
t=0
t=0.5hr t=1.0hr
t=0.5hr t=1.0hr
t=0.5hr t=1.0hr
Middle sleep mode wind pattern
t=0
t=0
t=0
Strong sleep mode wind pattern
Low sleep mode wind pattern
Strong rhythm sleep mode wind pattern
t=0.5hr t=1.0hr
t=0.5hr t=1.0hr
Middle rhythm sleep mode wind pattern
t=0.5hr t=1.0hr
Low rhythm sleep mode wind pattern
timer timeout
timer timeout
timer timeout
timer timeout
timer timeout
timer timeout
hours
hours
hours
hours
hours
hours
REV:1.0
SC2128A
Page 8 of 13
2004.08.03

Related parts for sc2128a-c30s