sc2434 Semtech Corporation, sc2434 Datasheet - Page 11

no-image

sc2434

Manufacturer Part Number
sc2434
Description
Sc2434 Triphase Current Mode Controller With Power Good
Manufacturer
Semtech Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
sc2434HTS
Manufacturer:
SC
Quantity:
123
Company:
Part Number:
sc2434HTS.TR
Quantity:
59 955
Part Number:
sc2434SW
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
Part Number:
sc2434SW.TR
Manufacturer:
SEMTECH
Quantity:
1 814
Part Number:
sc2434SW.TR
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
sc2434SWTR
Manufacturer:
ALCOR
Quantity:
1
Part Number:
sc2434SWTR
Manufacturer:
SC
Quantity:
20 000
PCB Layout Consideration
Good layout is necessary for successful implementation of the SC2434 based 3 tri-phase topology. There are few
general rules:
·
·
·
·
·
·
The following layout guideline gives details on how to achieve a good layout:
·
·
·
·
·
·
POWER MANAGEMENT
Applications Information (Cont.)
2005 Semtech Corp.
Reserve enough PCB space for the power supply (1.2~1.5 square inch for every 10A of load current);
Place enough high frequency ceramic capacitors inside and around the CPU socket (please follow CPU manufacture’s
decoupling guideline);
Place bulk output capacitors around the CPU socket as uniformly as possible. The connection copper between
these capacitors and the CPU socket must be short and wide to minimize inductance and resistance;
Always place the high power parts first;
Always use a ground plane or ground planes;
Always try to minimize the stray inductance of the high pulsating current loop which is formed by input capacitors
and the MOSFET half-bridges.
Input filter should contain mixed electrolytic capacitors and MLC capacitors. For every 20A of load current, use
about 10uF of MLC caps. Put MLC caps close to current sensing resistor;
Use surface mount current sensing resistor (typically 3~5 mOhm in surface mount package with low temperature
coefficient and low package inductance, typically less than 0.3nH);
Try to minimize the stray inductance from the current sensing resistor to the drains of the top FETs by using wide
trace (>0.5” wide and no more than 3” long). This trace can run on inner1 layer, for example, if the inner2 layer is
the ground plane, assuming the FETs are on the top layer. This arrangement forms so called strip line structure for
the pulsating power current, which yields least amount of stray inductance. The concept is depicted in Fig. 7;
Keep the layout as electrically symmetrical as possible, as shown in Fig. 8, to avoid very uneven stray inductance
from the sensing resistor to the drains of the top FETs;
Use a pair of closely paralleled traces to pick up the sensing voltage across the sensing resistor. The sensing traces
server as differential input to the OC+ and OC- pins of the SC2434 controller. These traces should run on a routing
layer (e.g., bottom layer for 4 layer PCB case) to avoid picking up strong AC magnetic field due to power current flow.
In this case, the differential sensing traces are shielded by the ground layer. The filter cap across the OC+ and OC-
pins should be placed as close as possible to the controller. Pay close attention that never allow power current
flowing on or running close by the sensing traces. Please see Fig. 8;
Separate power ground from analog ground to prevent power current from running over the analog ground plane.
The SC2434 controller should be placed on the quite analog ground area. The analog ground should be single-
point connected to the PGND near the output capacitor or the CPU socket to provide best possible ground sense.
Refer to the application schematics for those components should be connected directly to the AGND (Vcc decoupling
caps, cap on BGOUT pin, resistors on OSCREF pin, DACREF pin, FB pin, and PGIN pin).
Fig. 7 - Use MLC capacitors and strip line structure to minimize the stray inductance for the switching current loop.
VIA
MLC
Rsense
D
TOP FET
Ground Plane
11
S
D
BOT FET
S
VIA
www.semtech.com
SC2434